T-359
4–30
Figure 4.13 Alarm Troubleshooting Sequence
Cd60
Evaporator Fan
Pulsing
Temperature
Setting
CD60 contains a selectable temperature range used to determine the engagement
point of the Evaporator Fan Pulsing logic. Default setting is -18.1°C. The user may
change the temperature by pressing enter, then scrolling to the desired temperature
using either arrow key. Press Enter to accept the change. The temperature setting
will be retained until either a Pretrip or Trip Start is initiated at which time the tempera-
ture will set to the default setting.
Table 4–5 Controller Function Codes (Continued)
CODE #
TITLE
DESCRIPTION
Start
Troubleshooting
Unit
configured
correctly?
Pass
Pre--trip
inspection?
Active
Alarms?
Correct
software
version?
Did
Evaporator
fans start?
Operating
pressures
normal?
Check Power
Supply
Install Latest
Software
Revision
Load correct
unit
configuration
See alarm
details &
repair
Correct
all faults
Yes
Yes
Yes
Yes
No
Yes
No
Yes
No
No
No
No
Correct
Refrigerant
issue
Unit OK
Yes
No
Refer
to
CONNECT
POWER
Refer
to
CONNECT
POWER
Refer
to
CONTROLLER
SOFTWARE
Refer
to
Configuration
Software
(Variables)
Refer
to
Controller
Alarm
Indications
Refer
to
Pre--trip
Diagnostics
Refer
to
REFRIGERATION
SYSTEM
Check Power
Supply
Unit does
self test?
Содержание 69NT40-561-019
Страница 2: ......
Страница 4: ......
Страница 74: ......
Страница 127: ...8 3 T 359 Figure 8 2 SCHEMATIC DIAGRAM Evergreen Unit Configuration ...
Страница 128: ...T 359 8 4 Figure 8 3 UNIT WIRING DIAGRAM Evergreen Unit Configuration Sheet 1 of 2 ...
Страница 129: ...8 5 T 359 Figure 8 4 UNIT WIRING DIAGRAM Evergreen Unit Configuration Sheet 2 of 2 ...
Страница 130: ......
Страница 134: ......
Страница 135: ......