background image

Installation guide

LenelS2 Readers -  

5000 Series Standard

Содержание 5000 Series

Страница 1: ...Installation guide LenelS2 Readers 5000 Series Standard ...

Страница 2: ...olor Control features On Off Auto indicators Light itensity can be adjusted Indicators LED Green Red and Yellow Backlight in blue color Buzzer Power supply 9 to 30 VDC Current consumption 24 VDC idle mode with heater inactive 40 mA 12 VDC idle mode with heater inactive 50 mA Current consumption differs depending on functionality used and can also be limited in the reader configuration Input Output...

Страница 3: ...tensity can be adjusted Indicators LED Green Red and Yellow Backlight in blue color Buzzer Power supply 9 to 30 VDC Current consumption 24 VDC idle mode with heater inactive 60 mA 12 VDC idle mode with heater inactive 90 mA Current consumption differs depending on functionality used and can also be limited in the reader configuration Input Output 4 input for LED and buzzer control and 2 configurab...

Страница 4: ...IP65 Dimension W x H x D 79 x 109 x 25 Configuration method Configuration card reader tool software or factory configured readers Compliances 4 Lenel Readers 5000 Series Standard 13 56MHz 125kHz SF 2F Technical specifications Operating frequency 125kHz 13 56MHz Reading technologies Electromarine EM4200 HID Proximity MIFARE CSN 4 byte MIFARE CSN 7 byte MIFARE Classic MIFARE Plus MIFARE DESFire 0 6 ...

Страница 5: ...A 164 mA 108 mA Slimline 13 56 MHz with keypad Medium Low 50 mA 40 mA 217 mA 135 mA Slimline 13 56 MHz without keypad Low Low 50 mA 40 mA 152 mA 103 mA Slimline 13 56 MHz without keypad Medium Low 50 mA 40 mA 205 mA 130 mA Slimline Economy 13 56 MHz without keypad Low Low 35 mA N A 92 mA N A Slimline Economy 13 56 MHz without keypad Medium Low 35 mA N A 114 mA N A The above values are excluding he...

Страница 6: ...ont cover 2pcs Terminal connector 8 pin 2pcs Installation screws 2pcs Screw plugs 1pc Cable strip 1pc Fixing screw 1pc Quick installation guide Package content Please note that all pictures in this manual are illustrations and do not represent the actual sizes and form of the components ...

Страница 7: ...7 20 cm In order to facilitate installation a cable length of 20 cm is recommended ...

Страница 8: ...8 Ensure that the installation plate is fixed in the correct direction i e the arrows pointing upwards ...

Страница 9: ...tamper switch bulb of the installation plate is flat to be able to push the bulb for correct tamper alarm functionality If it is not flat enough you will find accessories in this manual that will assist with improving this functionality ...

Страница 10: ...ssory bag 1 Install the back plate on the wall with the supplied screws 2 Assemble the tamper alarm switch tray as shown in the picture 3 Remove the spring from the reader tamper alarm switch 4 Assemble the reader Tamper alarm will be in normal state as long as the reader housing is closed If the reader is opened the tamper alarm is activated Note that it is very important to remove the spring whe...

Страница 11: ...with the reader make sure to use a flat headed screw with a maximum height of 2 8 mm and a maximum diameter of 7 8 mm on the screw head Make sure not to tighten the screws too hard as doing so will deform and skew the installation plate This may affect the tamper switch functionality of the reader Countersunk screws should never be used 21 mm 48 mm 69 mm ...

Страница 12: ...hould be used a installation box tamperswitch bracket must be installed between the reader and the installation box Utilize screws supplied with the installation box but make sure to use a screw and possible also washer with a maximum height of 2 8 mm and a maximum diameter of 7 8 mm Tamper switch bracket for gangbox socket part no LNL R50000 TB 60 mm ...

Страница 13: ...13 P1 Blue socket P2 Black socket Make sure to place the terminal connectors with the fastening screws facing towards you ...

Страница 14: ...s a high quality shielded cable with minimum AWG18 dimension 0 8231 mm2 in an environment free from electrical noise A cable with smaller dimension or an installation environment with electrical disturbances will reduce the maximum cable length 2 Wiegand requires dedicated wires for external control of Green LED Red LED Buzzer and Keypad backlight 3 When utilizing the GPI O s each respective GPI O...

Страница 15: ...ed cable with minimum AWG20 dimension 0 5176 mm2 in an environment free from electrical noise with 12 V signal amplitude from controller 6 4 state Supervised F 2F requires 2pcs 1kOhm resistors Exit button must be connected to K LED and GND and Door sensor must be connected to BZ CTRL and GND See the following pages for wiring diagram LenelS2 Readers 5000 Series Standard Supervised F2 F T GPIO3 GPI...

Страница 16: ...state PIN Description F 2F SF 2F T GPIO3 Tamper output General purpose I O GPIO1 General purpose I O GPIO2 General purpose I O GND Ground X B RX RS485 OSDP A TX RS485 OSDP GND Power supply X X DC Power supply 9 to 30 VDC X X PIN Description F 2F SF 2F D RX Secondary RS485 D1 Wiegand Data 1 X X D0 Wiegand Data 0 D TX Secondary RS485 G LED External Green LED control X X R LED External Red LED contro...

Страница 17: ...te Reader Connection Supervised F 2F 2 state PIN Description F 2F SF 2F T GPIO3 Tamper output General purpose I O GPIO1 General purpose I O GPIO2 General purpose I O GND Ground X B RX RS485 OSDP A TX RS485 OSDP GND Power supply X X DC Power supply 9 to 30 VDC X X PIN Description F 2F SF 2F D RX Secondary RS485 D1 Wiegand Data 1 X X D0 Wiegand Data 0 D TX Secondary RS485 G LED External Green LED co...

Страница 18: ...cable is left in between the reader module and the installation plate Use the enclosed cable strip to fix the cable in the cord grip It is recommended to connect the the wires to the terminal connectors before tightening the cable strip ...

Страница 19: ...19 When installing the reader to the mounting plate ensure that the reader pin header contact perfectly aligns with the terminal connec tor block ...

Страница 20: ...er the image above and make sure it is fitted correctly In order to do so allign and fit the top snap fastening apply and main tain pressure on the top of the front cover while sliding the front cover over the bottom snap fastening ...

Страница 21: ...21 To secure the front cover to the reader use the supplied fixing screw and fix it into the installation plate through the front cover ...

Страница 22: ...er from the installation plate by inserting the tip of the tool into the slot at the bottom of the front cover and move the tool upwards This will release the front cover without damaging the front cover and or the installation plate Opening Tool reader housing part no LNL R50000 OT ...

Страница 23: ... Overview programming of reader Resetting the OSDP secure channel see page 26 Changing authentication card see page 25 Setting the reader in programming mode see page 23 Configuring the reader see page 24 ...

Страница 24: ...g card valid Authentication Card CHANGE Authentication Card Configuration Card or OSDP Installation Mode Card is presented within this time the reader will return to normal mode When a reader leaves programming mode it is indi cated by a blinking red LED and a beep Note Authentication Cards can be programmed to a pre initialized Authentication Card using the Authentication Card Tool Software and a...

Страница 25: ...ion card Note Configuration Cards can be programmed to a pre initialized Configuration Card using the reader tool software and a LenelS2 Readers 5000 series Reader connected to the reader tool using a RS485 to USB converter Reader tool software and connection cable set part no LNL R50000 TOOL LNL R50000 TOOL UK or LNL R50000 TOOL US Pre initialized configuration card part no LNL C5000 PCC Configur...

Страница 26: ...entication Cards can be programmed to a pre initialized CHANGE Authentication Card using the Authentication Card Tool Software and a LenelS2 Read ers 5000 series Reader connected to the Authentication Card Tool Software using a RS485 to USB converter Authentication Card Tool Software part no LNL 5000 ACT Reader tool software and connection cable set part no LNL R50000 TOOL LNL R50000 TOOL UK or LN...

Страница 27: ...n mode Note OSDP Installation Mode Cards Cards can be programmed to any MIFARE DESFire EV1 or EV2 cards using the reader tool software and a LenelS2 Readers 5000 series Reader connected to the reader tool using a RS485 to USB converter Reader tool software and connection cable set part no LNL R50000 TOOL LNL R50000 TOOL UK or LNL R50000 TOOL US BEEP Resetting the OSDP secure channel Reading distan...

Страница 28: ... SIM cards HID OmniKey 6121 has to be used with LNL R50000 SAM application LNL R50000 SIM to program Secure Access Modules LNL R50000 SAM LenelS2 Readers 5000 Series SAM Manager software Used together with LNL R50000 SAMTOOL LNL R50000 SIM to program Secure Access Modules Licensed application LNL R50000 SIM LenelS2 Readers 5000 Series SIM card unprogrammed Used together with LNL R50000 SAMTOOL LNL...

Страница 29: ...29 Accessories LenelS2 Readers 5000 Series Standard ...

Страница 30: ...ies card reader s back plate on uneven wall installations The acid resistant stainless steel spacer plate can be used to ensure full function of the tamper switch in the reader the spacer plate should be mounted behind the reader s back plate on uneven wall installations or similar environments Stainless steel spacer plate Spacer plate Std Combi LNL R50000 SPS ...

Страница 31: ...e the installation surface is uneven or and external wiring at the same side as the reader Can also be used when mounting readers over installation boxes Distance plate standard Standard Multi spacer Matte black part no LNL R50000 SPB Standard Multi spacer Matte white part no LNL R50000 SPW ...

Страница 32: ...allation holes or on uneven surfaces Can also be used with external wiring on the same side as the reader Distance plate large Standard Multi spacer for vandal protection Matte black part no LNL R50000 DPVPB Standard Multi spacer for vandal protection Matte white part no LNL R50000 DPVPW ...

Страница 33: ...33 Used to increase accessibility as well as visibility of the keypad Distance plate angled 10 Standard Multi Angled spacer 10 degrees Matte white art nr LNL R50000 DP10W ...

Страница 34: ... pin connects the tamperswitch to the installation surface the break off tamper indication is not functional with the distance plate angled 10o However if the reader body is removed from the installation plate the tamper alarm will still be activated if so configured in the reader tool Distance plate angled 10 Standard Multi Angled spacer 10 degrees Matte black art nr LNL R50000 DP10B Screws and s...

Страница 35: ...35 Distance plate angled 33 with QR code reader module Screws and screw plugs included with accessory Standard Angled spacer 33 degrees with QR code add on module Matte black part no LNL R50060 DP33B ...

Страница 36: ...x 5 6 x xxxx reader must be running on Firmware 3 82 09 or higher to use the QR module as an accessory Older firmware versions of LNL R50x 5 6 x xxxx readers will not detect the QR code reader Settings can be done with LenelS2 Reader Tool LNL R50000 tool version 6 5 0 7 or higher Green wire D RX White wire D TX Red wire DC Black wire GND Connection cable QR code module Sensor resolution 640 horizo...

Страница 37: ...ter of reader above the ground floor Note The reader can also be installed turned around 180 degrees for use on speed gates or tabletop readers for instance Distance plate angled 33 Screws and screw plugs included with accessory Standard Multi Angled spacer 33 degrees Matte black art nr LNL R50000 DP33B ...

Страница 38: ...ps it withstand violence by absorbing and redirecting external forces away from the reader Can be retro fitted to already installed readers Vandal protection Screws and screw plugs included with accessory Standard Multi Vandal protection Matte black part no LNL R50000 SPVPB ...

Страница 39: ...39 A recommended combination when external wiring is needed together with the vandal protection Can also be used for covering up old installation holes Distance plate large Vandal protection ...

Страница 40: ...ormat When installing readers in intense sunny conditions the white version LNL R50000 WRW is recommended to use as a shading accessory to provide an environ ment for the reader without direct intense sunlight In these condi tions it is also recommended to use white readers LNL R50000 WRW can also be used as PIN privacy protection and or increased climate protection A weather protection used in co...

Страница 41: ...eaning instructions Use compressed air in between the buttons to remove dust and dirt and after that isopropyl alcohol can be used with a piece of fabric to rub in between the buttons and the reader exterior ...

Страница 42: ...RSON OR ENTITY BUYING ITS PRODUCTS INCLUDING ANY AUTHORIZED DEALER OR AUTHORIZED RESELLER IS PROPERLY TRAINED OR EXPERIENCED TO CORRECTLY INSTALL FIRE AND SECURITY RELATED PRODUCTS More information on warranty disclaimers and product safety information please check https firesecurityproducts com policy product warning or scan the following code For all local contact details please consult the Carr...

Отзывы: