- 4 -

Table.4 a - POWER CONSUMPTION 42TW,42TD 3ROW

42TW,42TD

±

3 Row

@ 0 Pa ESP

@ 25 Pa ESP

@ 50 Pa ESP

Hi

Med

Low

Hi

Med

Low

Hi

Med

Low

-03

Amps

0.40

0.35

0.30

0.34

0.28

0.24

0.30

0.25

0.20

Watts

80

70

60

68

56

48

60

50

40

-05

Amps

0.45

0.40

0.35

0.37

0.32

0.27

0.33

0.28

0.22

Watts

90

80

70

74

64

54

66

56

44

-06

Amps

0.55

0.45

0.35

0.45

0.35

0.27

0.40

0.30

0.22

Watts

110

90

70

90

70

54

80

60

44

-07

Amps

0.60

0.50

0.40

0.50

0.40

0.30

0.45

0.35

0.25

Watts

120

100

80

100

80

60

90

70

50

-09

Amps

0.60

0.50

0.40

0.50

0.40

0.30

0.45

0.35

0.25

Watts

120

100

80

100

80

60

90

70

50

-11

Amps

0.90

0.80

0.70

0.75

0.65

0.55

0.65

0.55

0.45

Watts

180

160

140

150

130

110

130

110

90

-12

Amps

1.10

0.90

0.70

0.90

0.73

0.55

0.80

0.62

0.45

Watts

220

180

140

180

146

110

160

124

90

-16

Amps

1.20

1.00

0.80

1.00

0.80

0.62

0.80

0.70

0.50

Watts

240

200

160

200

160

124

160

140

100

Table.4 b

42TW,42TD

±

4 Row

@ 0 Pa ESP

@ 25 Pa ESP

@ 50 Pa ESP

Hi

Med

Low

Hi

Med

Low

Hi

Med

Low

-03

Amps

0.37

0.33

0.28

0.33

0.27

0.23

0.29

0.24

0.20

Watts

73

64

55

64

52

45

57

48

38

-04

Amps

0.42

0.37

0.33

0.36

0.31

0.26

0.32

0.27

0.22

Watts

82

73

64

69

60

50

63

53

42

-05

Amps

0.51

0.42

0.33

0.43

0.34

0.26

0.39

0.29

0.22

Watts

100

82

64

84

65

50

76

57

42

-06

Amps

0.56

0.47

0.37

0.48

0.38

0.29

0.44

0.34

0.24

Watts

109

91

73

93

75

56

86

67

48

-08

Amps

0.56

0.47

0.37

0.48

0.38

0.29

0.44

0.34

0.24

Watts

109

91

73

93

75

56

86

67

48

-10

Amps

0.84

0.75

0.65

0.72

0.62

0.53

0.64

0.54

0.44

Watts

164

145

127

140

121

103

124

105

86

-11

Amps

1.03

0.84

0.65

0.86

0.70

0.53

0.78

0.61

0.44

Watts

200

164

127

168

136

103

152

118

86

-14

Amps

1.12

0.93

0.75

0.96

0.77

0.60

0.78

0.68

0.49

Watts

218

182

145

187

150

116

152

133

95

Note: For 220V, 1 Phase Motor.

Table.5 a -SOUND PRESSURE 

42TW,42TD

±

3 Row

@ 0 Pa ESP

@ 25 Pa ESP

@ 50 Pa ESP

Hi

Med

Low

Hi

Med

Low

Hi

Med

Low

42TW3-03

47.5

45.5

43.5

46.5

44.0

42.5

45.5

42.5

41.0

42TW3-05

48.5

46.5

44.5

47.5

45.0

43.5

46.5

43.5

42.0

42TW3-06

50.0

48.0

46.0

49.0

46.5

45.0

48.0

45.0

43.5

42TW3-07

50.5

48.5

46.5

49.5

47.0

45.5

48.5

45.5

44.0

42TW3-09

50.0

48.0

46.0

49.5

47.0

45.5

48.5

45.5

43.5

42TW3-11

51.0

49.0

47.0

50.0

47.5

46.0

49.0

46.0

44.0

42TW3-12

51.0

49.0

47.0

50.0

47.5

46.0

49.0

46.0

44.5

42TW3-16

51.5

49.5

47.5

50.5

48.0

46.5

49.5

46.5

45.0

Table.5 b

42TW

±

4 Row

@ 0 Pa ESP

@ 25 Pa ESP

@ 50 Pa ESP

Hi

Med

Low

Hi

Med

Low

Hi

Med

Low

42TW4-03

46.5

44.5

42.5

46.0

43.5

42.0

45.0

42.0

40.5

42TW4-04

47.5

45.5

43.5

47.0

44.5

43.0

46.0

43.0

41.5

42TW4-05

49.0

47.0

45.0

48.5

46.0

44.5

47.5

44.5

43.0

42TW4-06

49.5

47.5

45.5

49.0

46.5

45.0

48.0

45.0

43.5

42TW4-08

49.0

47.0

45.0

49.0

46.5

45.0

48.0

45.0

43.0

42TW4-10

50.0

48.0

46.0

49.5

47.0

45.5

48.5

45.5

43.5

42TW4-11

50.0

48.0

46.0

49.5

47.0

45.5

48.5

45.5

44.0

42TW4-14

50.5

48.5

46.5

50.0

47.5

46.0

49.0

46.0

44.5

Note: Assumes "standard room ", 3 meters from exit, no ducts, ducts will further reduce sound

Содержание 42TD Series

Страница 1: ...rvicing air conditioning equipment can be hazardous due to system pressure and electrical components Only trained and qualified service personnel should install repair or service air conditioning equi...

Страница 2: ...hould be checked before the installation is started The installer should be familiar with each of the following requirements before the actual installation Space requirement and clearance See Fig 3 Ce...

Страница 3: ...outlet High speed 0 Static Table 3 Physical Data 42TW4 42TD4 4 Pipe System Model 42TW4 Model 42TD4 Size 03 04 05 06 08 10 11 14 CFM 313 533 623 702 795 1065 1247 1416 Cooling Capacity kw 3 4 5 3 6 9 8...

Страница 4: ...0 38 0 29 0 44 0 34 0 24 Watts 109 91 73 93 75 56 86 67 48 10 Amps 0 84 0 75 0 65 0 72 0 62 0 53 0 64 0 54 0 44 Watts 164 145 127 140 121 103 124 105 86 11 Amps 1 03 0 84 0 65 0 86 0 70 0 53 0 78 0 61...

Страница 5: ...7 1055 1091 16 2062 1575 1268 1770 1295 1530 H At High Fan Speed M At Medium Fan Speed L At Low Fan Speed Table 6 b Fan Performance 42TW 4 SI 42TW4 Air Flow m 3 hr Ex Static Pres Pa 0 12 5 25 37 5 Uni...

Страница 6: ......

Страница 7: ...age against available power supply For special installation consult local building and electrical codes INSTALLATION PLACING UNIT IN POSITION 1 Select the unit location Allow adequate space for free a...

Страница 8: ...unit to operate within duct external static pressure limits as shown on job submittals Units designed to operate with ductwork may be damaged if operated without intended ductwork attached Units provi...

Страница 9: ...inutes to prevent overloading 2 Operation Mode Selection Key Toggles the operation mode Cool Dry Heat or Fan only 3 Fan Speed Selection Key Toggles the fan speed Auto High Medium or Low Note Fan key i...

Страница 10: ...n Sleep function for healthy sleep to control automatically the room temperature and stop automatically the operation of the air conditioner after certain set off time Sleep mode is valid in cool or h...

Страница 11: ...WIRING SCHEMATIC 42TW TD COOL HEAT...

Страница 12: ...WIRING SCHEMATIC 42TW TD COOL HEAT WITHOUT CONTROL...

Страница 13: ...fan assembly remove front or bottom panel Fan assembly may be removed from its tracks if unit has a long conduit lead Use a stiff brush or vacuum to remove dirt and debris from scroll Wipe all fan sur...

Страница 14: ...t protected from direct foreign matter Cooling Heating Connections 13 Connect field piping to unit 14 Pressure test all piping for leaks 15 Install drain line traps as required 16 Insulate all piping...

Страница 15: ...NOTES...

Страница 16: ...Manufacturer reserves the right to discontinue or change at any time specifications or designs without notice and without incurring obligations...

Отзывы: