CLEANING, MAINTENANCE AND TROUBLESHOOTING

ELECTRICAL SHOCK HAZARD

Failure to follow this caution may result in personal injury or
death.
Always turn off power to the system before performing any
cleaning or maintenance to the system. Turn off the outdoor
disconnect switch located near outdoor unit. Be sure to
disconnect indoor unit if on a separate switch.

CAUTION

!

EQUIPMENT DAMAGE/OPERATION  HAZARD

Failure to follow this caution may result in equipment
damage or improper unit operation.
Operating the system with dirty air filters may damage the
indoor unit and could cause reduced cooling performance,
intermittent system operation, frost build−up on indoor coil
or blown fuses.

CAUTION

!

Periodic Maintenance

Periodic maintenance is recommended to ensure proper
operation of the unit. Recommended maintenance intervals may
vary depending on the installation environment, e.g., dusty
zones, etc. (refer to Table 2).

CUT  HAZARD

Failure to follow this caution may result in personal injury.

The coil fins are very sharp. Use caution when cleaning.

Always wear safety protection.

CAUTION

!

Cleaning the Coil

Clean the coil at the beginning of each cooling season, or when
necessary. Use a vacuum cleaner or a long−bristle brush to avoid
damage to the coil fins.

Air Filters

Remove and clean the air filters once a month.
NOTE: If air filters show signs of excessive wear or are torn,
they must be replaced. Contact your local dealer for
replacement filters.

1. Open the front panel.

A150660

Fig. 15 − Open the Front Panel

2. Remove the air filter.

A150661

Fig. 16 − Remove the Air Filter

3. Remove the carbon filter. Hold the frame’s tabs and remove

the four claws. The carbon filter can be renewed by
washing it with water once every 6 months. It is
recommended to replace the carbon filter every year.

Carbon Filter

A150680

Fig. 17 − Carbon Filter

4. Clean the air filter. A vacuum cleaner or pure water may

be used to clean the air filter. If the dust accumulation is
excessive, please use soft brush and mild detergent to
clean it and dry out in cool place.

IMPORTANT: The air−in side should face up when using vacuum
cleaner. The air−in side should face down when using water.

5. Set the air filter and the carbon filter as they were and close

the front panel. Operating the unit without the air filters may
result in equipment damage or even failure as dust will
accumulate inside the indoor unit.

EQUIPMENT DAMAGE HAZARD

Failure to follow this caution may result in equipment
damage.
When cleaning the front panel, do not use water hotter than
105

_

F (40.6

_

C) and do not pour water onto the fan coil. Do

not use abrasive or petroleum based cleaners as they may
damage the front panel.

CAUTION

!

Содержание 40MBFQ

Страница 1: ...umbers of your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful should your system require maintenance or service U...

Страница 2: ...eating the floor console fan coil unit matched with an outdoor condensing unit filters and dehumidifies the air in the room to provide maximum comfort IMPORTANT The floor console fan coil unit should...

Страница 3: ...OFF MO DE FAN SLC SLE EP SW ING DIR ECT TUR BO CLE AN LED FOL LOW Air flow louver at air outlet Air inlet with air filter inside Installation section Wireless remote controller Display panel Drain pip...

Страница 4: ...ature is O 86 F TEMP Decreases temperature in O 1 F 1 C increments Min temperature is O 62 F TIMER ON Sets timer to turn unit on TIMER OFF Sets timer to turn unit off SWING DIRECT Starts and stops lou...

Страница 5: ...5 INDOOR UNIT DISPLAY PANELS A150655 Fig 3 Display Panel Fig 4 Remote Controller...

Страница 6: ...lay ECO display Displays when SLEEP function is activated FOLLOW ME display Indicates that the FOLLOW ME function is on FAN SPEED display Displays selected FAN SPEED HIGH MED or LOW This display is bl...

Страница 7: ...programmed after insertion of new batteries Remote Control Operation Quick Start NOTE When transmitting a command from the remote control to the unit be sure to point the control toward the right side...

Страница 8: ...erature Selecting the Fan Speed AUTO LOW MED HIGH A14362 Fig 9 Fan Speeds The fan speed can be selected by pressing FAN NOTE When the unit is on the fan runs continuously in cooling or heating When in...

Страница 9: ...ioner automatically determines the appropriate blowing pattern based on the operating mode or situation Table 1 Operating Mode OPERATING MODE COOL MODE HEAT MODE Situation When the room totally cools...

Страница 10: ...Use TURBO to cool or heat the room rapidly a Press TURBO An audible beep is heard if the indoor unit supports this function The fan runs on super high speed The TURBO mode terminates automatically 20...

Страница 11: ...age to the coil fins Air Filters Remove and clean the air filters once a month NOTE If air filters show signs of excessive wear or are torn they must be replaced Contact your local dealer for replacem...

Страница 12: ...ntrol Batteries S S S S OUTDOOR UNIT EVERY MONTH EVERY 6 MONTHS EVERY YEAR Clean Outdoor Coil from Outside Clean Outdoor Coil from Inside Blow Air Over Electric Parts Check Electric Connection Tighten...

Отзывы: