2–3
T-372
2.5.6
Autotransformer
An autotransformer may be provided to allow operation on 190/230, 3-phase, 50/60 Hz power. The
autotransformer raises the supply voltage to the nominal 380/460 volt power required by the base unit. The
autotransformer may also be fitted with an individual circuit breaker for the 230 volt power.
2.5.7
Handles
The unit may be equipped with handles to facilitate access to stacked containers. These fixed handles are located
on either side of the unit.
2.5.8
Water Cooling
The refrigeration system may be provisioned for a water-cooled condenser. The condenser is constructed using
copper nickel tube for sea water applications.
2.5.9
Back Panels
Aluminum back panels may have access doors and/or hinge mounting.
2.5.10
460 Volt Cable
Various power cable and plug designs are available for the main 460 volt supply. The plug options tailor the cables
to each customer’s requirements.
2.5.11
230 Volt Cable
Units equipped with an autotransformer require an additional power cable for connection to the 230 volt source.
Various power cable and plug designs are available. The plug options tailor the cables to each customer’s
requirements.
2.5.12
Cable Restraint
Various designs are available for storage of the power cables. These options are variations of the compressor
section cable guard.
2.5.13
Upper Fresh Air Makeup
The unit may be fitted with an upper fresh air makeup assembly. The fresh air makeup assembly is available with a
Vent Positioning Sensor (VPS) and may also be fitted with screens.
2.5.14
Labels
Safety Instruction and Function Code listing labels differ depending on the options installed. Labels available with
additional languages are listed in the parts list.
2.5.15
Controller
The controller is a Carrier Transicold Micro-Link 5 microprocessor. Refer to
for more information.
Controllers will be factory-equipped with the latest version of operational software, but will NOT be configured for a
specific model number and will need to be configured at the time of installation or sale.
Two replacement controllers are available:
1. Re-manufactured - Controller is equivalent of a new OEM controller, supplied with a 12-month warranty.
2. Repaired - Controller has had previous faults repaired and is upgraded with the latest software.
NOTE
Repaired controllers are NOT to be used for warranty repairs; only full OEM Re-manufactured
controllers are to be used.
2.5.16
Condenser Grille
Condenser grilles are direct bolted.
Содержание PrimeLINE 69NT40-571-001
Страница 2: ......
Страница 4: ......
Страница 14: ......
Страница 36: ......
Страница 110: ......
Страница 116: ......
Страница 171: ...8 1 T 372 SECTION 8 ELECTRICAL WIRING SCHEMATIC AND DIAGRAMS Figure 8 1 Legend Standard Unit Configuration ...
Страница 172: ...T 372 8 2 ELECTRICAL WIRING SCHEMATIC AND DIAGRAMS Figure 8 2 Schematic Diagram Based on Drawing 62 11957 ...
Страница 176: ......
Страница 178: ......
Страница 180: ......
Страница 184: ......
Страница 185: ......