MASTERseries Release 6.01 - Quick Start Guide
47
Alarms and Diagnostics
Alarms
Alarms
The alarms screen is available in the TUI.
The alarms screen displays the current status of each link, port and power supply
installed in the chassis. None of the fields on this screen are editable. At the bottom
of the screen is an alarm status summary for the entire chassis and a listing of slots currently in alarm.
Interfaces will appear as
d
, or
Diag
when a loopback, BERT or both are active on the interface.
Press
R
to refresh the display.
A (Alarms)
Alarms
sTat Diag pOrt Link tImeslot clK Connect coMmit aPs Setup Flex
----- EDIT: CFG 1 ------------------------------------------ RUN: CFG 1 -------
LINK DS3 PORT ETH MSRV
<-----------------> <-> <--> <-> <----------------->
M Tn ABCD 111 1111 EFGH 111 1111
# S En MODULE TYPE 1234 5678 9012 3456 123 1234 12 1234 5678 9012 3456
- - -- -------------- ---- ---- ---- ---- --- ---- -- ---- ---- ---- ----
1 M T1 FLEXmaster16
UUUU UUUU u UD uuuu uuuu uuuu uuuu
2 -
3 -
4 -
5 -
6 -
7 -
8 -
Power Supply 1 Up Fans Down
Power Supply 2
Up
u=Unassigned U=Up D=Down I=Init d=Diag O=Off (Disabled)
---------------------------------- GREEN ---------------------------------
Alarms: Clk: INT Jan 25, 2005 11:29