R
IS1132A(07/11)
(SIDE 1 OF 2)
Fig. 1
1
2
3
4
9
10
11
12
15
17
16
14
Inlet Connection End
13
Mixer Connection End
Deck
5
6
7
8
18
19
20
21
22
Spigot
Important Information
3)
4)Flexible Tail Inlet Connections: Connect the flexible tails (16)
to the hot and cold isolating stop taps, hand tighten the
connecting nut (15) until rubber cone contacts the sealing
face of the connection end, then tighten a further one turn
to provide a watertight joint.
Important: Flexible tails must not be kinked, twisted or in
tension when installed. (Minimum Bend Radius:- 50mm)
Do not install flexible tails where subject to ultra violet light.
Insert the inlet connection end (15) of each flexible tail (16)
through the hole in the deck. Place mixer over deck hole, fit
gasket (11) and fixing plate (12) over stud (13) then screw
on fixing nut (14). Position mixer as shown, ensure
caroma
marking on base ring (9) is facing towards the front, then
tighten fixing nut (14) using a suitable spanner.
All pipework must be thoroughly flushed prior to
installation, as foreign materials may block the
flow regulating device and reduce the flow of water.
Note: Aerator insert housing must be retightened
to prevent removal by hand.
*
Isolating stop taps must be fitted to the hot & cold water
supply connections. (Part No. 842018C - Mini cistern 1/4T)
*
*
* Not suitable for gravity feed systems.
Mixer is fitted with a 7.6 L/min flow regulated aerator insert.
If swivel spout (22) is required to be fitted, first place retainer
(18) in spigot groove (19). Ensure 'O' rings are well lubricated
then slide the swivel spout (22) over spigot, taking care that
the hole in the swivel spout (22) aligns with the retainer hole.
Fit screw (20) and tighten with 2mm allen key (21) provided.
5)
2) Flexible Tail Mixer Connections: Apply suitable lubricant to
'O'rings (17). Fit flexible tail (16) (with red indication) into
hole marked with a Red Dot in underside of mixer body (8).
Hand tighten the tail, ensuring the 'O'ring (17) has fully
entered the sealing bore to provide a watertight joint. Fit
other flexible tail (with blue indication) into remaining hole
in a similar manner.
1) From fixing pack fit 'O'ring (10) into groove in base ring (9).
Screw stud (13) into underside of mixer body (8). Locate
spigot of base ring (9) into base of mixer body (8).
Laundry Mixer Installation
PLUMBERS INSTALLATION INSTRUCTIONS
CIRRUS - LAUNDRY MIXER SET
WATER EFFICIENT TAPWARE
(NOMINAL FLOW RATE = 7 L/min)
Replacing Cartridge
Turn off hot and cold water supplies.
Carefully remove plug (4) before using a 2.5mm allen
key (3) to loosen grub screw (2) and remove handle (1).
Remove cap (5) taking care not to damage the decorative
finish. Unscrew nut (6) then lift out old cartridge (7).
Ensure inside face of mixer body (8) is clean. Check that
seal (21) is in position in base of new cartridge (7). Fit new
cartridge (7) into mixer body (8), taking care that two lugs
on base of cartridge (7) fit into mating holes in mixer body (8).
Screw on nut (6).
Important: Nut (6) should be tightened
to a torque of 10 Nm.
Replace cap (5), tightening by hand. Fit handle (1) taking
care that it is pushed fully down, then tighten grub
screw (2). Replace plug (4) taking care not to damage
the decorative finish.
Turn on water supplies and check operation.
1)
2)
3)
4)
5)
6)
Hot and cold water inlet pressures should be equal.
Static inlet pressure range : 150-1000 kPa
IMPORTANT
Pressure & Temperature Requirements.
Deck thickness : 45mm maximum
Deck Requirements
Maximum hot water temperature : 80 C.
Tap body hole (in deck) : 34-36mm
New Regulation:- 500 kPa maximum static pressure
at any outlet within a building.