CP3 version 3003
61
Table for Cable Length, Cross Section and Number of Sensors in a Line
The table below can help decide upon cable length and number of sensors in a line from cabinet to sensor 1
and between the sensors.
An example could be:
50 sensors in a line using a 1.5mm
2
cable. Distances between sensors are 3.0 m.
The result from the table is the following:
Maximum cable length from the cabinet to first sensor in line is 69 m
Maximum cable from sensor 1 to sensor 50 is 150 m
Table 1
1
2
4
5
Cable C-1
40
50
2.5 m 3.0 m 3.5 m Cable 1-
X
130
X
X
100
120
X
X
120
110
X
X
140
81
X
X
125
69
X
X
150
56
X
X
175
1.
Cable length in m between cabinet and sensor 1
2.
Number of sensors on a line
3.
Distance between sensors in m
4.
Cable in m between sensor 1 and sensor X
Please contact your Carlo Gavazzi Sales office if you have any questions regarding the calculations, or if you