WA R N I N G
!
NOTE
CAUTION
!
WA R N I N G
!
NOTE
SERVICE LEVEL
Personnel who service this unit must be qualified electronics
technicians. Replacement parts are designed to be made
at the assembly level. See “Parts Identification” section
of this manual for part numbers and ordering information.
ALWAYS
turn power to the power supply
OFF
,
unplug the electrical cord from its outlet, remove the
front panel fuse, and lock the power supply out before
making repairs or replacements.
DO NOT
attempt to make repairs to the printed
circuit board!
DO NOT
attempt to make repairs beyond those
described. All others should be made
ONLY
by
Ransburg service personnel.
REPLACEMENT PROCEDURES
Before making replacements, check for defective wiring or
connections between the affected components. If there is
a broken wire, defective insulation, or dirty, loose or cor-
roded connections, repair or replace them before going to
the expense of replacing a component.
ALWAYS double check that the power supply is
unplugged from its AC outlet before working with any
internal wiring.
It is recommended that the four ON/OFF switch
wires be tagged with their respective terminal connec-
tions to 1SW before removing.
Two (2) spare fuses, included from the factory, are
located on the inside of the top lid of the cabinet.
Fuses 1FU & 2FU
1. Insert screwdriver into slot into the respective fuse holder,
push in, and rotate counter-clockwise.
2. Remove screwdriver and fuse holder will slide out.
3. Remove fuse from fuse holder and replace with new
fuse (See “Parts Identification” section of this manual
for part numbers).
4. Insert fuse holder back into front panel and with a slight
inward pressure, rotate screwdriver clockwise until it
locks into place.
5. Secure cabinet lid and plug power supply back in.
ON/OFF Switch 1SW
1. Ensure power supply is unplugged from AC outlet and
open cabinet lid.
2. Remove the four quick connect terminals from the rear
of ON/OFF switch 1SW.
3. Press panel retaining clips on top and bottom of switch
1SW together and push switch out of panel from the
inside.
4. Press new switch (See “Parts Identification” section of
this manual for part numbers) into panel opening with
terminals 1A and 2A to the bottom of the cabinet.
5. Reconnect the four quick connect terminals to the new
switch as follows:
To
From
1LF-RED or BLACK
1SW-1
1LF-BLUE 1SW-2
2TB-3 1SW-1A
2TB-4 1SW-2A
6. Secure cabinet door and plug power supply back in.
High Voltage Multiplier
1. Remove HV cable from power supply.
2. Ensure power supply is unplugged from AC outlet and
open cabinet lid.
CP-13-03-R4 (05/2020)
28 / 35
www.carlisleft.com
MAINTENANCE
EN