OPERATION
WA R N I N G
!
NOTE
Figure 8: Controller Start-Up Display
The controller comes preconfigured for the No. 2 Process
Handgun from the factory. The following table lists the
display value and jumper settings for the unit. This table is
a
reference
to verify that the gun configuration jumpers are
in their correct positions if unexpected behavior is observed.
VERIFY
that the gun jumper configuration is set for
the applicator type that is being used for the system.
DO NOT
adjust the gun configuration jumpers. If they
are incorrect, contact your Ransburg representative.
USE ONLY
the gun type configuration for the No.
2 Process Handgun (80102-21X). Using the wrong
configuration may allow for operation outside the rec-
ommended parameters and values for the applicator
and can result in
damage
or
un-safe operation
.
BASIC OPERATIONS
The basic operations are general operations that
are available.
Triggering High Voltage
High voltage is actuated by the presence of an active trigger
signal. This is accomplished by turning the on-off switch
of the No. 2 Process Handgun to the “on” position. The
kV is displayed on the kV display, the actual current draw
on the µA display, and the high voltage light illuminates.
Under the µA display is a bar graph meter that illuminates
according to the actual current draw shown in Figure 9.The
green and yellow regions of the bar graphs meter indicate
output current is in the optimum range for maximum transfer
efficiency. The red region of the bar graph indicates high
output current causing decreased transfer efficiency. If
high output, check maintenance of applicator and external
equipment of the power supply.
START-UP
After all installation procedures are completed, operation
of the applicator may begin. When the ON-OFF switch is
turned on, the kV display will show the applicator type the
9060 Controller is configured for and the µA (microamp)
display will show the current software revision level as shown
in Figure 8. These items are displayed for approximately
5 seconds after the board powers up.
After the initial start-up delay, the unit will be configured for
the applicator based on the gun type jumper settings and
is ready for standard operation.
During start-up, the gun on-off switch should
NOT
be in the on position. If this switch is ON it will cause
a non-resettable boot fault (bF) and prevent the unit
from being operated. This is designed to prevent un-
intended firing of the high-voltage immediately after
start-up. Please refer to the “Fault Section” of this
manual for more information.
Description
Type
START-UP DISPLAY
99
No. 2 Process Handgun (Electric Motor)
13
Jumpers
GUN TYPE NUMBER
SOFTWARE REVISION LEVEL
OFF-ON SWITCH