NOTE
CAUTION
!
WA R N I N G
!
SAFETY GROUND
Crimp the appropriate connector onto the ground wire as-
sembly and install from the Controller ground stud, located
on the side panel, to a true earth ground.
INPUT VOLTAGE SELECTION
The 9060 Controller accepts universal input voltage be-
tween 100 and 240 VAC at 50 or 60 Hz. There is no need
to change any switch settings when changing input from
110 to 240 VAC or from 240 to 110 VAC.
All 9060 units
(80102-21X) shipped from the fac-
tory for either 110 VAC input or 240 VAC input will
have a 72771-06, 1 Amp front panel fuses installed.
Figure 6: Installation of Conduit Adapter Plate
HIGH VOLTAGE CABLE
Position the No. 2 Process Handgun in the spray area
and route the high voltage cable to the Controller. The
cable should be routed so that it is not damaged by foot
and vehicle traffic and also so that is not close to areas
of high temperature (129°F+). The operator should have
free movement of the applicator and all bend radii of the
cable should not be less than 6-inches (15 cm). Connect
the high voltage cable to the Controller and tighten the
retaining nut and set screw. If during the routing of the
high voltage cable it is required to remove it from the No.
2 Handgun, care should be taken when reinstalling so that
the high voltage cable is completely engaged.
The Controller
MUST
be
OFF
when the No. 2
Handgun is removed or reinstalled.
Do
NOT
rely on the ground connection provided
by generators and other portable power generation
devices.
The ground wire assembly
MUST
be connected
from the Controller ground stud to a
true earth
ground
.
NO. 2 PROCESS HANDGUN
TRIGGER SIGNAL
The No. 2 Process Handgun (80102-21X) uses the on-off
switch on the back of the gun to activate the trigger input
at J3-5. This signal causes the PC mainboard to turn on
the high voltage.
CP-13-03-R4 (05/2020)
15 / 35
www.carlisleft.com
INSTALLATION
EN