FUSES
Fuses
There are two (2) time delay fuses (250V, 1A, 5mm x
20mm) installed in fuse holders on the connection interface.
They are located directly above the ground lug connection.
They are present to provide a measure of safety against
power surges through the AC input. The top fuse holder
is connected in series between the HOT line (L) input
connection and the Interlock AC line connection terminal
1TB-L2. The bottom fuse holder is connected in series
between the neutral AC input connection and the neutral
input connection of the AC line power filter.
Spare Fuses
The Controller also comes with two (2) spare fuses (250V,
1A, 5mm x 20mm) mounted in holders, inside the lid of
the Controller.
SIGNAL INTERFACE
The 9060 Controller, when configured for use with the No.
2 Process Handgun, requires only one signal input for
operation, the trigger signal.
The trigger signal input (J3-5) is controlled directly from
the on-off switch located on the No. 2 Process Handgun.