Location of Control Unit
Install the low voltage control unit in an area
outside the
hazardous location
in accordance with federal, state, and
local codes. The area should protect the control unit from
the possibility of environmental intrusion (such as dust or
moisture), have ambient temperatures that do not exceed
120
°
F, and be as close to the applicator as possible to
minimize the length of low voltage cable.
The control unit
MUST
be located outside of the
spray area.
The User
MUST
read and be familiar with the
"Safety" section of thismanual.
This manual
MUST
be read and thoroughly
understood by
ALL
personnel who operate, clean, or
maintain this equipment! Special care should be taken
to ensure that the warnings and requirements for
operating and servicing safety are followed. The user
should be awre of and adhere to
ALL
local building
and fire codes and ordinances as well as NFPA,
OSHA, and all related country safety codes prior to
installing, operating, and/or servicing this eqiupment.
The fluid lines and fluid sources
MUST
be
isolated from ground for waterbase applications.
Personnel
MUST
be
GROUNDED
to prevent a
shock or spark during electrostatic operation.
Install and route the hoses and cable so they are
NOT
exposed to temperatures in excess of 120° F
and so that all hose and cable bends are
NO LESS
than a 6 inch (15cm) radius. Failure to comply with
these parameters cold cause equipment malfunction
that might create
HAZARDOUS CONDITIONS!
Install only one spray applicator per isolated
waterborne fluid supply system.
NEVER
wrap the applicator, associated valves
and tubing, and supporting hardware in plastic to
keep it clean. A surface charge may build up on the
plastic surface and discharge to the nearest ground-
ed object. Efficiency of the applicator will also be
reduced and damage or failure of the applicator
components may occur.
WRAPPING THE APPLI-
CATOR IN PLASTIC WILL VOID WARRANTY.
Only approved applicator covers should be used.