77-3128-R2 (10/2022)
1 / 8
www.carlisleft.com
240-2012-AC
ACID COMPATIBLE CCV VALVE
(COMPATIBLE WITH STRONG ACIDS SUCH AS PTSA)
Some materials and catalysts are extremely dangerous.
Wear proper PPE during installation and maintenance.
Consult the material SDS sheet for specific
PPE requirements.
!
WARNING
Know your operating pressures! Use only Binks hoses and
fittings rated for the required operating pressures for use
with this product. See maximum air and fluid pressure for
each model listed in the specifications.
!
WARNING
SPECIFICATIONS
Maximum air inlet pressure (both models):
7 bar [105 psi]
Air requirements (operating pressure):
4.8-6.9 bar [70-100 psi]
Air inlet connection port:
M5 x 0.8 (f)
Maximum fluid pressure:
69 bar [1000 psi]
Fluid connection ports (2x):
1/4" NPT (f)
Valve actuation speed (ON/OFF cycles):
55 cycles/min
Pressure Drop w/ 70 cP Test Fluid:
(Varies w/ material press. and viscosity)
1 PSI press. drop @ 500 PSI and 200 cc/min
7 PSI press. drop @ 500 PSI and 1000 cc/min
43 PSI press. drop @ 500 PSI and 3800 cc/min
EN
SERVICE MANUAL