5.3 Adjust the Pressure Power
The pressure power of the printhead can be set with the pressure
regulator. The values are indicated in the following table:
NOTICE!
If the pressure power is too low then the printhead has no
more contact to the counter-pressure plate. Due to the missing
heat dissipation while printing the printhead is damaged. An
error message appears in case of too less pressure. This error
message serves to prevent overheating the printhead and is
not suitable as pressure quality monitoring. The print quality is
also reduced with too low pressure.
'Lift' indicates the distance between the printhead and counter-
pressure plate in idle mode of device.
Recommended pressure power:
40 N
Max. pressure power:
45 N
As the mechanical wear and tear of the printhead increases with the
pressure power, the pressure power should be as low as possible.
Содержание FLEXICODE 53
Страница 1: ...FLEXICODE Operating Manual ...
Страница 8: ...Introduction Flexicode 8 Operating Manual 11 19 ...
Страница 14: ...Machine Overview Flexicode 14 Operating Manual 11 19 ...
Страница 18: ...Operating Conditions Flexicode 18 Operating Manual 11 19 ...
Страница 40: ...Installation and Initial Operation Flexicode 40 Operating Manual 11 19 ...
Страница 44: ...Operation Panel Flexicode 44 Operating Manual 11 19 ...
Страница 94: ...Maintenance and Cleaning Flexicode 94 Operating Manual 11 19 ...
Страница 100: ...Signal Diagrams Flexicode 100 Operating Manual 11 19 ...
Страница 114: ...Additional Information Flexicode 114 Operating Manual 11 19 ...
Страница 116: ...Environmentally Friendly Disposal Flexicode 116 Operating Manual 11 19 ...