Specifications
P7000, P6000, TIVA, TCI & TIVA 76/106
1000SM00012 Issue 8
Electromagnetic Compatibility (Model P7000)
Warning:
•
The use of any accessory, transducer, or cable with the IVAC® P7000 Syringe Pump other than those specified may result in
increased emissions or decreased immunity of the pump.
•
The IVAC® P7000 Syringe Pump should not be used adjacent to or stacked with other equipment, however if adjacent or stacked
use is necessary, the IVAC® P7000 Syringe Pump should be observed to verify normal operation in the configuration in which it will
be used.
Caution:
•
The IVAC® P7000 Syringe Pump is a CISPR 11 Group 1 Class A Medical Equipment System and intended for use by healthcare
professionals only.
•
Medical Electrical Equipment needs special precautions regarding EMC and needs to be installed, put into service and used
according to the EMC information provided in the accompanying documents.
•
Portable and Mobile RF communications can affect Medical Electrical Equipment.
•
Operating the pump near equipment which radiates high energy radio frequencies (electro surgical or cauterizing equipment,
portable radios, cellular telephones, etc.) may cause false alarm conditions. If this happens, reposition the pump away from the
source of interference or turn off the pump and manually regulate the flow.
Guidance and Manufacturer’s Declaration – Electromagnetic Emissions
The IVAC® P7000 Syringe Pump is intended for use in the electromagnetic environment specified below.
The customer or the user of the IVAC® P7000 Syringe Pump should assure that it is used in such an environment.
Emissions Test
Compliance
Electromagnetic Environment – Guidance
CISPR 11
RF Emissions
Group 1
The pump uses RF energy only for its internal function in the normal product
offering. Therefore, its RF emissions are very low and are not likely to cause any
interface in nearby electronic equipment.
CISPR 11
RF Emissions
Class A
The pump is suitable for use in all establishments, other than domestic, and
those directly connected to the public low-voltage power supply network that
supplies buildings used for domestic purposes.
EN 61000-3-2
Harmonic Emissions
Class A
EN 61000-3-3
Voltage Fluctuations,
Flicker Emissions
Complies
Содержание IVAC P6000
Страница 1: ...s IVAC Syringe Pumps Models P7000 P6000 TIVA TCI TIVA Technical Service Manual...
Страница 35: ...Chapter 4 Troubleshooting In this chapter Introduction 36 Error Codes 36 General Fault Diagnosis 38...
Страница 87: ...Appendix C Fitting and Replacement Guidelines...
Страница 98: ...Appendix E Disposal...
Страница 101: ...Appendix E Service Contacts...
Страница 103: ...Appendix F Document History...
Страница 105: ...Page Intentionally Left Blank...