background image

UI SmartSeat seat height supplemental iss02, 07/2014

The CareFlex 

Smart

Seat 

Seat Height Adjustment

CareFlexibility

Class 1 

Medical Device

TM

TM

Содержание SmartSeat Small

Страница 1: ...UI SmartSeat seat height supplemental iss02 07 2014 The CareFlex SmartSeat Seat Height Adjustment CareFlexibility Class 1 Medical Device TM TM ...

Страница 2: ...g themselves or with minimal assistance the seat height should be set so that the client s feet rest flat on the floor and the underside of their thighs are in contact with the full length of the seat cushion If the seat height is too high the client s heels will be lifted off the floor and pressure will build up along the underside of their thighs If the seat is too low their knees will be raised...

Страница 3: ...ace with two bolts Use a 5mm allen key and a 13mm spanner to undo the two bolts holding the interface bracket in place and carefully lower the Tilt action to rest on the floor Put the bolts and nuts in a safe place ready for re fitting at the end of the height adjustment process Remove both of the chair arms as per the main SmartSeat user instructions Undo the zip holding the two halves of the cru...

Страница 4: ...g a socket wrench with a 13mm socket There are five nuts each side and the two rear nuts can be obscured by the sides of the back frame depending on the seat depth adjustment of the chair Adjust the seat depth so that all five nuts from each side can be accessed and removed Keep the nuts in a safe place for future re fitting The side panels are now only held in place by the arm fitment trim plates...

Страница 5: ... page 2 for dimensions for each seat height on the appropriate size chair Work on one side of the chair at a time Carefully lift up a side panel and use a 17mm spanner to undo the bolts controlling seat height Raise or lower the pivot plate so that the bolts can be re fitted back through the appropriate height setting holes and in to the fitments on the castor frame Ensure the bolts on both front ...

Страница 6: ...nch Only three to four threads should protrude from the end of the nut to ensure they are not over tightened Over tightening the nuts will damage the side panels and cause interference with the seat depth mechanism especially on the small chair On manual chairs re fit the legrest release lever into the aperture on the right base side panel Push the lever in firmly making sure the lever overlaps th...

Страница 7: ...tting the middle two holes the mid point setting and the top two holes the highest setting It is essential that the interface bracket is fitted between the correct holes Never attempt to re position the interface bracket in an attempt to increase or decrease the range of Tilt in Space Position the interface bracket in the main bracket on the frame crossbar and line up the appropriate set of holes ...

Страница 8: ...8 To find out more or to book a free no obligation product demonstration please Call 0800 0186440 Email enquiries careflex co uk Visit www careflex co uk ...

Отзывы: