background image

CCM3A-2216-EU-PIR-MKX

MOVEMENT MONITOR 11/12/13

USE MAINS POWER SUPPLY

PS3A-2207-UK ONLY

SILENT ALERT SA3000 SYSTEM

WWW.SILENTALERT.IE Silent Alert International

TEL +353 (0)1 247 9007

MOVE KEY D

OWN 

TO SWIT

CH ON

Chair leaving monitor

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

  1 = System Co

de 1

  2= System

 Code 2

  3 = System Co

de 3

  4 = System Co

de 4

  5 = 

Audio

 Monitor

ing

  6 = Zone Multipl

ier (7

-12)

  7 = Short 

Audio

 Delay

  8 = Medium

 Audi

o Delay

  7 & 8 = Long 

Audio

 Delay

  9 = PIR Delay 5 Mins

10 = PIR Delay 10

 Mins

9 & 10 = PIR Dela

y 15 m

ins

11 = Zone 6

12 = Zone 5

13 = Zone 4

14 = Zone 3

15 = Zone 2

16 = Zone 1

MOVE KEY D

OWN 

TO SWIT

CH ON

PUSH

Status light

Test button

Configuration 

switch Cover

PP3 battery 

contacts

Screw cap

Screw cap

CCD4A-2220-EU 

CARE CALL 

MINI MAGNETIC

DOOR MONITOR

USE ALKALINE PP3 
9 V BATTERY ONLY

Batch 06/01/14 

www.silentalert.ie 

Silent Alert International, Ireland 

Tel: +353 (0)1 247 9007

  Keys 1-4 System 

Channel

  Key 5=10 Sec Delay
  Key 6=20 Sec Delay

Keys 5+6=30 Sec Delay

  Key 7 Leave ON  

Key 8 Not Used

USE WITH MAGNET SUPPLIED

PP3 Battery

PUSH

PUSH

The light will then will flash 

green several times to show the 

battery voltage. 

9 flashes = 9Volts in the battery. 

When a battery is first fitted the 

indicator light will flash red then 

green a few times then light 
solid green & pause briefly.  

1.

Install a 9 volt PP3 alkaline or lithium battery 

making sure to observe the correct polarity.

PUSH

If the light flashes red at this 

point the battery is flat  

and will need to be replaced. 

To repeat the battery check remove the battery, press the test 

button then re-insert the battery to start the sequence again.

CCD4A-2220-EU 

CARE CALL 

MINI MAGNETIC

DOOR MONITOR

USE ALKALINE PP3 
9 V BATTERY ONLY

Batch 06/01/14 

www.silentalert.ie 

Silent Alert International, Ireland 

Tel: +353 (0)1 247 9007

  Keys 1-4 System 

Channel

  Key 5=10 Sec Delay
  Key 6=20 Sec Delay

Keys 5+6=30 Sec Delay

  Key 7 Leave ON  

Key 8 Not Used

USE WITH MAGNET SUPPLIED

Pressure pad 

socket

PUSH

1 2 3 4 5 6 7 8

Configuration switches shown with 

cover removed. Do not alter these 

without referring to page 2

2.

The monitor is activated using an under carpet 

pressure pad (PM5). 

Connect the PM5 plug into the socket on the monitor. 

The connection can be taped for added security 

if required. 

The monitor may transmit the first time the connection is 

made, this is normal. 

4.

As the user stands up the monitor will send a 

signal to the Pager or SignWave. 

3.

Place the Pad under the chair cushion ensuring 

the pad is not folded.  

When installing the pad make sure the cable can't 

cause a trip hazard.   

5.

PUSH

Fidget delay

To prevent the unit triggering 

when the user changes position in 

their seat the monitor has a  

'fidget' delay.

If the person releases the 

pressure from the pad a timer will 

start, this is indicated by the green 

light flashing on the monitor.

After 3 - 4 seconds the monitor will trigger.

However, if the person sits back down the light will 

switch off and the monitor will not transmit.  

Care

Call

Quick start guide CCC4A-2212-EU

Care Call Mini Chair Leaving Monitor

Any questions? Call us on

+353 (0)1 247 9007

Silent Alert International

www.silentalert.ie

+353 (0)1 247 9007

Отзывы: