17
SYSTEM MANAGEMENT OPERATIONS
Attention!
Before memorising the transmitters for the first time remember to cancel the entire memory
content.
• Memorizing a channel code
1. Press and hold down button
"P1"
, LED
"L2"
will flash slowly.
2. At the same activate the transmitter channel to be memorised,
"L2"
will remain lit for 2 seconds
indicating that the channel has been memorised; if the LED keeps flashing slowly the channel was
already memorised. Only one channel can be memorised at a time. To insert another channel repeat
points 1 and 2 after having released the button. When the code memory is complete (1000 transmitters
memorised) you may only memorise a new transmitter after you have completely cancelled an existing
transmitter or after cancelling the entire memory content.
• Deleting a channel code (via an associated transmitter)
1. Press the button
"P1"
twice and hold down after pressing the second time: LED
"L2"
will flash at brief
intervals.
2. Activate the transmitter channel to be cancelled,
"L2"
will remain lit for 2 seconds indicating that the
channel has been cancelled;.
To cancel another channel repeat points 1 and 2 after having released the button.
• Deleting the entire code memory content (users)
- Press
"P1"
three and hold down after pressing the third time. During the cancellation procedure (3-4
seconds) LED
"L2"
remains lit. After cancellation the LED will flash 3 times; at this point release the
button.