1
UNIT FAILS TO OPERATE WHEN MAINS POWER SWITCHED ON.
a. If red LED above is NOT LIT:–
–
Remove power lead 13A plug from supply socket.
–
Use test lamp to check power is available at the 13A socket.
–
Check fuse in 13A plug (NB should be fitted with a 5A Fuse.)
–
Remove power lead from the Autoglide unit.
–
Check fuse in the Autoglide power input socket (see Figure 25)
N.B.
Should be fitted with a 250v 2A slow blow
×
20mm long fuse.
b. If Red L.E.D. above is LIT:–
–
Check if unit can be operated from either :–
i
The remote handset.
ii
The button on the control unit (provided child lock is disabled,
shown by a flashing green LED).
iii The remote bell push button.
If any of the these operate the door then the unit is functioning
properly.
The ’start’ methods that failed to operate the door will need to be
checked out separately, see in later sections.
–
Should the unit fail to operate by any of the above “start” methods:–
i
Turn the power switch on the unit to the OFF position.
ii
Wait for 5 seconds then turn back ON again. This will re-set the
control system.
iii Re-try “start” methods as above.
2
MOTOR OPERATES BRIEFLY BUT DOOR REMAINS FULLY CLOSED.
(the LED flashes briefly RED)
–
Door not de-latching correctly
–
Check adjustment/operation of latches (Section 4.8)
–
Check position/setting of tilt bracket (Section 4.2)
3
MOTOR OPERATES BUT DOOR DOES NOT MOVE (MOTOR RUNS ON)
(the LED flashes intermittent RED)
–
Motor drive not engaged
–
Check drive pin correctly engaged (Section 5)
4
MOTOR OPERATES BUT DOOR FAILS TO FULLY OPEN OR CLOSE.
(the LED flashes briefly RED)
i
Turn OFF mains power to unit and read safety notes at the front
of this manual.
22