21
9
When correctly connected ensure all terminal screws are
tight, tighten the cable clamp and refit the connector cover.
10
Plug lamp output connector into the Autoglide unit.
(see Figure 28)
11
Tidy up mains input, lamp output and bell wire cables
using the cable clamp (item 6) and 2 off No 6
×
1
/
2
" pan head self tap
screws provided. (see Figure 28) DO NOT OVERTIGHTEN.
12
Switch mains power back on to the unit and test the lamps and the
bell push by operating the door.
The lamp should come on as soon as the door is operated and go off
automatically after approximately 3 minutes.
IMPORTANT NOTE:
This unit can only be used with INCANDESCENT
lamps. It must not be used with fluorescent or halogen lamps.
Connect blue
wire to terminal
N
N
E
L
Connect yellow/green
wire to ear th
Connect brown wire
to Ter minal L
•
Figure 27
Upon completion of installation and when handing over to the end user
the installer should carry out the following:–
1
Grease latch pins and latch cam, and ensure all screws and fixings are
fully tight.
2
Check manual operation of the door to ensure correct balance.
3
Check operation of drive unit over full open/close cycle to ensure
correct functioning.
4
Carry out Safety Sensitivity check.
5
Instruct end user in location and use of the Manual Release lever.
6
Explain function of Child Lock safety feature on the button.
NOTE:
If in doubt ensure that the child lock is ENABLED so that door
CANNOT be operated from the button (see
Section 6c
).
7
Ensure the User manual is left with the end user, as this contains
important safety and warranty information.
10 Final checks
Lamp out
connector
Mains input
connector
Cable clamp
and screws
•
Figure 28