CARBEL H-100 Plus Скачать руководство пользователя страница 1

 

 

 

INSTRUCTION MANUAL 

 

 

Models:  

 

  

- H-100 Plus 

- H-80 Plus 

- H-50 Plus  

- H-100 Plus Double Sided

 

 

 

 

 

 

 
 
 
 
 
 

 
 
 

COCINAS CARBEL 

C/ Ciudad de Cartagena, 22 

46988 Polígono Industrial Fuente de Jarro (Paterna) 

Valencia 

Tel. 96 1340716   Fax: 96 1340449 

E-mail: [email protected] 

 

 

 

Содержание H-100 Plus

Страница 1: ...L Models H 100 Plus H 80 Plus H 50 Plus H 100 Plus Double Sided COCINAS CARBEL C Ciudad de Cartagena 22 46988 Pol gono Industrial Fuente de Jarro Paterna Valencia Tel 96 1340716 Fax 96 1340449 E mail...

Страница 2: ...all local regulations including those that refer to national and European standards Instructions for the chimney Correct operation depends on the chimney draught Tips for optimal performance The wood...

Страница 3: ...days Water causes more damage to woodburners than the high combustion temperatures for which they are prepared When the pipes run through the inside of the home or a brick chimney they should be mount...

Страница 4: ...can cause problematic reverse chimney draughts Instructions for Installation The installation of the appliance must comply with all local regulations including those that refer to national and Europe...

Страница 5: ...r against the sides of the appliance Leave a minimum expansion joint of 0 5 cm on each side and at least 1 cm the top of the front Fitting the legs Turn the appliance over onto its back Insert the leg...

Страница 6: ...is installed It has an air inlet through a piece for a flue of 120 mm First fit the screw on the air inlet piece leaving a few millimetres of separation to insert the tab with the screw recess Put the...

Страница 7: ...lling the turbine optional Models H 100 Plus H 100 Plus double sided and H 80 Plus Remove in this order the woodholder that protects the glass Remove the primary air inlet nozzle Remove the fireplace...

Страница 8: ...Unscrew the eight screws and remove the turbine access cover Remove the convection chamber vent by breaking the micro couplings Fit the turbine and tighten the screws...

Страница 9: ...Replace the turbine access cover and tighten the screws Replace the base the air inlet nozzle and the woodholder that protects the glass...

Страница 10: ...the turbine optional Model H 50 Plus Remove the vent at the bottom of the convection chamber by breaking the micro couplings Fit the turbine directly from the outside tighten the screws and fit the ai...

Страница 11: ...optimal stability and support of the appliance we recommend you install the two supplied brackets Use the supplied screws to fasten the two brackets to the top of the appliance Screw the brackets to t...

Страница 12: ...e appliance to the floor In order to ensure the proper anchoring of the appliance to the floor you can use the metal legs designed for said purpose The choice of suitable bolts will be the fitter s re...

Страница 13: ...Fitting the New Line vertical frame model H 50 Dekor New Line Screw the top and bottom panels to the side panels Top panel Side panels Bottom panel...

Страница 14: ...Remove the fireplace door and position and screw the New Line frame to the front of the appliance Refit the door Frame fixing screws...

Страница 15: ...nlet If you see that the volume of flames decreases or tends to go out open the air inlet or repeat step 3 When you reload with more wood if there are not enough flames or embers to light the new load...

Страница 16: ...the fire During operation adjust the combustion with the secondary air inlet according to the chimney draft and the wood used Schematic of the primary and secondary air inlet adjustment controls Close...

Страница 17: ...d which must be done as quickly as possible Do not take a long time when loading firewood and wait for the end of the combustion cycle when the flames of the previous load disappear A full combustion...

Страница 18: ...combustion when you have less need for heat or for overnight maintenance always preceded by a cycle of more power with thinner firewood when the appliance temperature is already high If necessary when...

Страница 19: ...TIONS OF WARRANTY The manufacturer guarantees the product for a term of five years excluding parts subject to normal wear and tear The warranty excludes fibre seals ceramic glass and removable parts o...

Страница 20: ...be installed on floors with sufficient bearing capacity Observe the minimum safety distances from nearby combustible materials In front of the appliance minimum 90 cm Combustible materials must not be...

Страница 21: ...Double sided fireplace Fireplace Fireplace Fireplace Fireplace...

Страница 22: ...kg 1 5 kg Reload interval for rated power 0 78 h 0 8 h 0 74 h 0 72 h Max admitted load 4 kg 4 8 kg 3 kg 2 9 kg Required draft 12 Pa 12 Pa 12 Pa 12 Pa Average temp of fumes Weight kg 125 150 110 100 D...

Страница 23: ...arbel S L C Ciudad de Cartagena 22 Pol gono Industrial Fuente del Jarro 46988 Paterna VALENCIA CERTIFICATE OF WARRANTY NAME ADDRESS TOWN CITY POSTCODE PROVINCE TEL E MAIL MATERIAL EXCLUDED FROM WARRAN...