WSD12PS-4AI
User Manual
PAGE 7
WA0285E_WSD12PS-4AI_User Manual_R06 V6.0
www.
capetti
.it
8.
Wireless device user interface.
The user interface consists of a “virtual” button that can be activated using the
and of a two-colours led.
To give a command, user must approach the
to the device’s sensible area and keep it in that position.; the following picture
shows device’s sensible points
.
The following COMMAND table describes the available commands:
WIRELESS MODE COMMAND table
Flash count
Command
Description
1 flash
STATUS
Shows the device STATUS. As answer the led perform a flash sequence as reported in
the STATUS table. If the device is performing the TEST (
refer to TEST command
) this
command stops it.
2 flashes
TEST
Enter in TEST mode and transmits status and measurements every 5 seconds. If the
device is in STANDBY mode or it is out of radio range, this command forces the
connection procedure to the WSN and the return to the operative mode. The TEST
stops after 120 seconds. During TEST, the led continuously shows the STATUS to
monitor the received radio signal quality.
CAUTION: Measures acquired during TEST phase are NOT saved.
3 flashes
ENROLL
Association to the network: must be used when the device has not yet been included
in a network, starts the entry and association procedure to the gateway (
refer to
WineCap System - User Manual R30
4 flashes
+ 4 flashes
STANDBY
Temporary device deactivation: the device is stopped. The sampling process and the
radio are/is. turned off losing the connection to the network. To reactivate, a TEST
command is necessary. The STANDBY command must be given twice to confirm it: at
the first sequence the led flashes alternating RED and GREEN lights, waiting for the
second confirm sequence within 15 seconds. At the command execution the led
flashes as the STANDBY status (
Picture 8 - Status table - Radio signal quality
).
5 flashes
+ 5 flashes
FACTORY RESET
The device performs the memory deleting procedure and goes in STOP status. All
samples, configuration and wireless network data associated are LOST. To reactivate
the device a new association and configuration procedure is necessary (
ENROLL
command
). Also in this case, the FACTORY RESET command must be given twice to
confirm it. At the command execution the led flashes as the “PROBE/DATALOGGER
NOT ASSOCIATED” status
(
refer to “
Picture 8 - Status table - Radio signal quality
).
5 flashes
+ 3 flashes
LOGGER
NO WSN
As the previous command but performs only the WSN deleting procedure and
disassociate from the gateway. The device enters in LOGGER STAND ALONE mode:
data are kept, and the sampling activity CONTINUES with previous setup. Command
must be given with 2 sequences: 5 flashes and then 3 flashes. At the command
execution wait for the device reboot. At the STATUS command, “
LOGGER
” will be the
answer (
refer to “
Picture 9 - Stand-alone device - Status table
). A new association (
ENROLL
command
) is possible to a new gateway.
Picture 7 - Command table
Picture 6 - WineCapKey positioning
LED
WineCapKey
Содержание WSD12PS-4AI
Страница 1: ...WSD12PS 4AI User Manual ...