WSD12PS-4AI
User Manual
PAGE 3
WA0285E_WSD12PS-4AI_User Manual_R06 V6.0
www.
capetti
.it
3.
Selecting the generated power supply
The device supplies for a specified time (
programmable warm-up time using
from 1 [default] to 32 seconds
) a DC voltage on PS+ pin
of the terminal block. The value of the DC voltage can be selected using J12 (
Errore.
L'origine riferimento non è stata trovata.
):
DC voltage generated for a specified time:
24Vdc @ 100mA
DC voltage generated for a specified time:
12Vdc @ 100mA (
default
)
Picture 3
–
Jumper positions
Removing jumper J10 (
Errore. L'origine riferimento non è stata trovata.
), voltage generation on pin PS+ of the terminal block is disabled. This situation
may be useful in case the DC voltage is not necessary. Consequently, the battery life is increased.
4.
Full-scale setting
The measurement’s full
-scale selection, is done positioning a jumper on the proper strip:
0÷25mA input
(
default
)
0÷5Vdc input
0÷10Vdc input
0÷25Vdc input
Picture 4 - Full-scale setup
The measurement acquired is displayed as percentage of the selected full-scale.
5.
Measurement’s scale impedance
Input
Input’s impedance
0÷25mA
100Ω
0÷5V
24KΩ
0÷10V
16KΩ
0÷25V
13.
333KΩ
Picture 5 - Input impedance