Mechanical dimensions. 

 

Picture 12 - Mechanical dimensions

 

17.

 

Warnings. 

 

In case of batteries substitution, DO NOT disconnect the flat cable which connect the electronic boards without removing batteries 
before 

 

ALWAYS substitute all the batteries, also in case of one single battery exhausted 

 

During the installation/configuration procedure, disconnect the jumper 10 to avoid transducers or devices connected to the PS output 
(

Capetti

’s

 electronics is provided with short-circuit and over-absorption protections, but transducers can be damaged in case of wrong connections 

or inverted polarities

). 

 

 

Follow the manufacturer's suggested warm-up time (

time required to obtain a reliable measurement

) of the transducer. 

 

Follow the manufacturer's suggested electric wiring of the transducer to measure (

ground shields at a single point, cable length and section

); 

voltage measures on distances exceed 15/20 meters are subjected to electromagnetic disturbances. 0

÷

25mA inputs have a superior 

electromagnetic compatibility (

EMC

). 

 

• Avoid passage in cavities with power or high voltage cables.

 

 

The protection and 

safety measures and the warranty provided by the Manufacturer with the equipment may be compromised if it’s 

used in a manner that does not comply with this user manual. 

 

This equipment complies with CE regulations. 

 

This equipment can receive any interference which could also cause unwanted behaviour. 

 

Modifications or tampering not expressly approved by the Manufacturer could void the user's authorization to operate the equipment. 

 

This equipment must be installed by qualified personnel. 

 

The  device  has  a  weight  of  up  to  0.450  kg.  Make  sure  that  the  object  is  properly  fixed  to  supports/infrastructures  capable  of 
withstanding this load. Make sure proper methods and materials are used when fixing the equipment to a wall. 

 

Only service personnel authorized by the manufacturer or personnel expressly authorized by the latter can open the container. There 
are no user serviceable parts inside. 

 

 

Содержание WSD12PS-4AI

Страница 1: ...WSD12PS 4AI User Manual ...

Страница 2: ...p to 100mA distributed on 4 analog channels Measurements acquired are expressed in percentage of full scale 2 Channel description Picture 1 Product image SHIELD shield cable connection PS INPUT datalogger generated voltage negative pole Input signal negative reference INPUT Signal input 0 25mA 0 5Vdc 0 10Vdc 0 25Vdc Full scale selectable using scale jumpers PS datalogger generated voltage positive...

Страница 3: ...c 100mA default Picture 3 Jumper positions Removing jumper J10 Errore L origine riferimento non è stata trovata voltage generation on pin PS of the terminal block is disabled This situation may be useful in case the DC voltage is not necessary Consequently the battery life is increased 4 Full scale setting The measurement s full scale selection is done positioning a jumper on the proper strip 0 25...

Страница 4: ...PS 4AI can be programmed using WineCapManager to supply a warm up time variable from 1 default to 32 seconds Be sure that the device is linked to its gateway refer to 10 Installation procedure Run WineCapManager and open the plant related database If the database doesn t exist and the gateway is not properly licensed on connected PC refer to WineCap System User Manual R30 From the WineCapManager m...

Страница 5: ...ww capetti it Click on InfoReq button Select the card Calibration Modify the Zero field with the desired warm up value default 1 maximum 32 The inserted value is expressed in seconds and represents the duration of output power supplied to transducer net off 0 4s of tolerance ...

Страница 6: ...ociate it make reference to the WineCap System User Manual R30 software manual It is necessary to use the WineCapManager software on the PC connected to the gateway that will be linked with the device b USB Logger Mode For this operation mode stand alone with data downloads through USB the connection with the PC and the WineCapManager running on it is necessary to modify the device s operation mod...

Страница 7: ...flashes STANDBY Temporary device deactivation the device is stopped The sampling process and the radio are is turned off losing the connection to the network To reactivate a TEST command is necessary The STANDBY command must be given twice to confirm it at the first sequence the led flashes alternating RED and GREEN lights waiting for the second confirm sequence within 15 seconds At the command ex...

Страница 8: ...TUS RADIO SIGNAL QUALITY 5 green flashes ACTIVE Radio signal Excellent 4 green flashes ACTIVE Radio signal Good 3 green flashes ACTIVE Radio signal Fair 2 amber flashes ACTIVE Radio signal Sufficient 1 red flash ACTIVE Radio signal Insufficient 1 red flash 2 long OUT OF RANGE Network searching 2 red flashes 2 long STANDBY Radio off No Logging Short long short red flashes series FACTORY RESET Devic...

Страница 9: ...time you can issue the STANDBY command refer to Picture 7 Command table It corresponds to the command number 4 and must be issued twice to confirm the operation Position the WineCapKey in the spot indicated in Picture 6 WineCapKey positioning and wait for four AMBER flashes then remove the WineCapKey from device Verify that the device asks for confirmation of STANDBY command with alternate GREEN R...

Страница 10: ... up to 100mA Selectable onboard using jumpers Warm up time From 1 default to 32 seconds Selectable using WineCapManager Sampling interval Selectable from one minute to 24 hours 60 minutes default Datalogger capacity 64 000 samples for each channel Working temperature Operative 30 C 60 C Warehousing 40 C 70 C Radio frequency ISM 868MHz Radio coverage Up to 6Km in line of sight can be extended using...

Страница 11: ...ion voltage measures on distances exceed 15 20 meters are subjected to electromagnetic disturbances 0 25mA inputs have a superior electromagnetic compatibility EMC Avoid passage in cavities with power or high voltage cables The protection and safety measures and the warranty provided by the Manufacturer with the equipment may be compromised if it s used in a manner that does not comply with this u...

Страница 12: ...nic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point The end user should contact the device provider either the manufacturer or the...

Отзывы: