For each flash, a different command is associated; to confirm the command the 

WineCapKey

 must be removed from the sensible 

area immediately after the number of flashes corresponding at the desired command. The 

TEST

 corresponds to the second pulse 

and activate the "

Field

 

Measurer

" function.

 

 

The device will give back the radio signal quality through led flashes: 

WIRELESS MODE STATUS

 Table 

Flash count - Wireless mode 

Status/Radio signal quality 

 

5 green flashes 

Excellent 

 

4 green flashes

 

Good

 

 

3 green flashes

 

Fair

 

 

2 amber flashes

 

Sufficient

 

 

1 red flash 

Insufficient 

 

1 red flash 2” long 

OUT OF RANGE 

Network searching 

 

2 red flashes 2” long 

STANDBY 

 

Short-long-short red 

flashes series  

FACTORY RESET 

Device not enrolled

 

 

Optimize reception selecting the best position: small movements can help. 

If the signal is absent or insufficient at the install point, 

WR12

 

router

 should be put between (

refer to 

WineCap System - User Manual 

R29

). Th

WR12

 

router

 

itself must be located in a position where the signal level is at least sufficient. 

The network will reconfigure itself automatically; the signal will be good again when the device synchronizes with the 

WR12

 

router

The link will not be reconfigured until completely lost by the device. Because of this, in some cases it could be necessary to force 
the operation. In such cases, put the device in 

STANDBY

 mode, then run the 

TEST

 again (

refer to “

WineCap System - User Manual R29

). 

NOTE

: The display equipped 

datalogger

 (

WD04T

) is recommended, to verify the signal quality during devices installation. 

7.

 

Stand-alone USB datalogger installation. 

Install the 

datalogger

 in appropriate place. 

If the sampling process has not yet been activated you can start it through the 

WineCapKey

 

Bring it closer to the sensitive point, wait for 2 flashes (

TEST

) (

refer to 

Picture 5 - Commands table

and remove. The 

datalogger

 begins 

sampling according to your settings through your PC. 

Through th

WineCapKey

 is possible to ask for the current status, bring it close to the 

datalogger

 for 1 flash (

STATE

) and remove it. 

STAND-ALONE MODE STATUS 

Table:  

Flash count - Stand-alone mode 

STATUS 

 

1 green flash 2 seconds long 

ACTIVE 

 

2 red flashes 2 seconds long 

STANDBY 

 

Sequence  of  red  flashes:  short,  2 
seconds long, short 

FACTORY RESET  

INVALID

 

datalogger

 clock! 

PC connection required 

 

Picture 6 - Status table - Radio signal quality

 

Picture 7 - Stand-alone datalogger status

 

Содержание WineCap WSD12T-IIDR

Страница 1: ...1 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it 1 9 1 Description The WSD12T IIDR is a datalogger provided with vertical mounting transducers with 3 input channels to acquire inclination an temperature with storage functionality of samples acquired External transducers measures the horizontal axis inclination Picture 1 Product Image Picture 2 Measured axes ...

Страница 2: ...function and repeat the reset process WineCapManager software shows and if necessary reset the offset stored in the device using a remote radio command ELECTRONIC LEVEL and RESET READING features are available and works the same for the second tilt channel channel 3 Issue command 7 to use these features on channel 3 the first time for the ELECTRONIC LEVEL twice for RESET READING 3 Device preset an...

Страница 3: ...becomes a wireless datalogger and besides sending new measures to the basestation starts a download process towards the same basestation of the measures acquired during the stand alone period refer to Picture 7 Stand alone datalogger status 4 Wireless device user interface The user interface consists of a virtual button that can be activated using the WineCapKey and of a two coloured led To give a...

Страница 4: ...mples configuration and wireless network data associated are LOST To reactivate the device a new association and configuration procedure is necessary ENROLL command Also in this case the FACTORY RESET command must be given twice to confirm it At the command execution the led flashes as the PROBE DATALOGGER NOT ASSOCIATED status refer to WIRELESS MODE STATUS Table refer to STAND ALONE MODE STATUS T...

Страница 5: ...be located in a position where the signal level is at least sufficient The network will reconfigure itself automatically the signal will be good again when the device synchronizes with the WR12 router The link will not be reconfigured until completely lost by the device Because of this in some cases it could be necessary to force the operation In such cases put the device in STANDBY mode then run ...

Страница 6: ...refer to Picture 5 Commands table Its corresponds to the command number 4 and must be issued twice to confirm the operation Position the WineCapKey in the spot indicated in Picture 4 WineCapKey positioning and wait for four AMBER flashes then remove the WineCapKey from device Verify that the device asks for confirmation of STANDBY command with alternate GREEN RED flashing then position again the W...

Страница 7: ...Datalogger ABS Transducers galvanized iron bracket covered with polybutadiene resin Mounting Datalogger fix on 4 points Transducers fix on 2 points with 4 gross correction Connections Wireless USB 3m cable lenght for each transducer Inclination Transducer type Uniaxial MEMS technology 1 15 Dual Range Automatic Autoscale Inclination Measure range 1 15 Inclination Measure accuracy 0 5 of sample Incl...

Страница 8: ...ual_R05 V4 6 CAPETTI ELETTRONICA s r l Strada Stratta 57 10090 CASTIGLIONE TORINESE TORINO ITALY VAT 04837130014 Phone 011 981 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it 8 9 10 Mechanical dimensions Picture 8 Mechanical dimensions ...

Страница 9: ...11 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point T...

Отзывы: