Capetti Elettronica Wine cap WSD10TGII Скачать руководство пользователя страница 7

 

WSD10TGII 

User Manual

 

 

 

 

 

WA0375E_WSD10TGII_User Manual_R08 

V4.6

 

 

CAPETTI ELETTRONICA s.r.l.  -   Strada Stratta 57 
10090 CASTIGLIONE TORINESE  -  TORINO  -  ITALY 
VAT 04837130014 - Phone 011.981.98.11 -  Fax 011.981.98.210 
e-mail [email protected]  -  web www.capetti.it

 

 

 

7/9

 

 

10.

 

Technical Information. 

Power supply

 

19A/h - 3,6V type “D” lithium internal battery 

Battery life (*)

 

Up to 14years  

(samples every  60 minutes and radio signal quality at least sufficient)

 

 

Measures acquired 

(4 input channels

 

 

Peak acceleration 

 

Biaxial inclination 

 

Temperature 

Sampling interval 

(

*

)

 

Selectable from one minute to 24 hours 

(60 minutes default)

 

Datalogger capacity

 

64,000  samples

 

(

for each channel

)

 

Working temperature

 

 

Operative: -30°C ÷ +60°C 

 

Warehousing: -40°C ÷ +70°C  

Radio frequency

 

ISM 868MHz

 

Radio coverage

 

Up to 6Km in line of sight 

(can be extended usin

WR12

 battery powered routers)

 

Sealing

 

IP65

 

Dimensions

 

90 x 120 x 50mm

 

Weight

 

550g

 

Case material

 

ABS

 

Mounting

 

4 points

 

Connections

 

Wireless  USB 

Acceleration - Transducer Type

 

Triaxial accelerometer - MEMS technology   

Acceleration - Measure Range

 

±16g 

Acceleration - Measure Resolution

 

100mg 

Acceleration - Alarms

 

Common setup on three axis 

Inclination - Transducer Type

 

Triaxial accelerometer - MEMS technology   

Inclination - Measure Range

 

±180° 

Inclination - Measure Accuracy 

±1.5° 

Inclination - Measure Resolution

 

<1° 

Inclination - Alarms

 

Common setup on both axis 

Temperature - Transducer type

 

NTC10KΩ

 

Temperature - Measure range

 

-30°C ÷ +60°C

 

Temperature - Measure accuracy

 

 

± 0.5°C  Range -30°C ÷ 0°C

 

 

± 0.2°C  Range 0°C ÷ +60°C

 

Temperature - Measure resolution

 

0.01°C

 

* battery life may be influenced by fieldwork conditions, sampling/measuring interval and system configuration

** radio coverage reachable using up to 3

WR12 routers

 (maximum 16 for each path) between the device and the basestation. 

 

 

Содержание Wine cap WSD10TGII

Страница 1: ...ird party external intelligence PLC PC ecc Concerning the MWLI MB 4AO basestation the received information let the basestation to immediately close either relay equipped onboard and physically turn on an external alarm device Please note the datalogger must not be installed upside down with 180 tilt because the result means a discontinuity point and data acquired are wrong the datalogger stores an...

Страница 2: ...edure Otherwise in case the device is in FACTORY RESET mode refer to Picture 5 Status table Radio signal quality that means it s ready for connecting to an existing system in order to associate it make reference to the WineCap System User Manual R29 software manual Is necessary to use the WineCapManager software on the PC connected to the basestation that will be coupled with the device b USB Logg...

Страница 3: ...etti it 3 9 5 Wireless device user interface The user interface consists of a virtual button that can be activated using the WineCapKey and of a two coloured led To give a command user must approach the WineCapKey to the device s sensible area and keep it in that position the following picture Picture 3 WineCapKey positioning shows device s sensible points Picture 3 Device positioning Picture 4 Wi...

Страница 4: ...opped The sampling process and the radio are is turned off losing the connection to the network To reactivate a TEST command is necessary The STANDBY command must be given twice to confirm it at the first sequence the led flashes alternating RED and GREEN lights waiting for the second confirm sequence within 15 seconds At the command execution the led flashes as the STANDBY status refer to WIRELES...

Страница 5: ...fferent command is associated to confirm the command the WineCapKey must be removed from the sensible area immediately after the number of flashes corresponding at the desired command The TEST corresponds to the second pulse and activate the Field Measurer function The device will give back the radio signal quality through led flashes WIRELESS MODE STATUS Table Flash count Wireless mode Status Rad...

Страница 6: ...h count Stand alone mode STATUS 1 green flash 2 seconds long ACTIVE 2 red flashes 2 seconds long STANDBY Sequence of red flashes short 2 seconds long short FACTORY RESET INVALID datalogger clock PC connection required 9 Shutting off Reactivating the device If the device is shut off and left unused for a long time you can issue the STANDBY command refer to Picture 4 Commands table Its corresponds t...

Страница 7: ...ght can be extended using WR12 battery powered routers Sealing IP65 Dimensions 90 x 120 x 50mm Weight 550g Case material ABS Mounting 4 points Connections Wireless USB Acceleration Transducer Type Triaxial accelerometer MEMS technology Acceleration Measure Range 16g Acceleration Measure Resolution 100mg Acceleration Alarms Common setup on three axis Inclination Transducer Type Triaxial acceleromet...

Страница 8: ...l_R08 V4 6 CAPETTI ELETTRONICA s r l Strada Stratta 57 10090 CASTIGLIONE TORINESE TORINO ITALY VAT 04837130014 Phone 011 981 98 11 Fax 011 981 98 210 e mail info capetti it web www capetti it 8 9 11 Mechanical dimensions Picture 8 Mechanical dimensions ...

Страница 9: ... 65 CE that restricts the use of substances in the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point The...

Отзывы: