Webster 64
Page 31 of 32
Installation Manual
February 2024 • Rev. 1.1
ALARM SHUNT OUTPUT
The (
MF
) multifunction relay is factory configured as
Alarm Shunt
. When an access-
granted or an exit button event occurs, the alarm shunt output relay is activated first
followed by the lock output relay. The relay can be used to bypass an external alarm
point. When an access-granted or an exit button event is complete, the lock output is
turned off followed by the Alarm Shunt output after a short delay. If a door contact is
used then Alarm Shunt output is turned off shortly after the door contact is closed.
DOOR OPERATOR OUTPUT – ALL CARDS
The (
MF
) multifunction relay, when configured as
Door Operator - All Cards
,
will be
activated by all cards and by exit button press. The lock relay will be activated first
followed by a one second pulse on this
MF
relay which is used to trigger the door
operator.
DOOR OPERATOR OUTPUT – HANDICAP CARDS ONLY
The (
MF
) multifunction relay, when configured as
Door Operator - Handicap Cards
Only
,
will only be activated by cards designated as handicap and by exit button press.
The lock relay will be activated first followed by a one second pulse on this
MF
relay
which is used to trigger the door operator.
DHO OR FORCED ENTRY
The (
MF
) multifunction relay, when configured as
DHO or Forced Entry
,
will be
activated on either
Door Held Open
event or
Forced Entry
event. A message will be
recorded and displayed in Webster 64 transaction log.
© Cansec Systems Ltd., 2023 All rights reserved
Содержание Webster 64
Страница 1: ...Webster 64 Controller INSTALLATION MANUAL September 2023...
Страница 13: ...Webster 64 Page 13 of 32 Installation Manual February 2024 Rev 1 1 Figure 6 Non Supervised...
Страница 14: ...Webster 64 Page 14 of 32 Installation Manual February 2024 Rev 1 1 Figure 7 Supervised...
Страница 32: ...Webster 64 Page 32 of 32 Installation Manual February 2024 Rev 1 1...