background image

 

 

SmartLock

®

 Controller 

INSTALLATION MANUAL 

November 2018 

Содержание SMARTLOCK Series

Страница 1: ...SmartLock Controller INSTALLATION MANUAL November 2018...

Страница 2: ...5 Communications Device 12 READER WIRING 13 Wiegand Reader 13 iButton Reader 14 LOCK OUTPUT RELAY WIRING 15 DC Electric Strikes 15 DC MagLocks 16 AC MagLocks and AC Electric Strikes 17 INPUT WIRING 18...

Страница 3: ...123A Specifications Notice When using a pluggable 16 VAC standard 40 VA transformer Maximum Continuous Current no battery attached 2 amps for 12 VDC on the Output Maximum Continuous Current battery at...

Страница 4: ...cess and SmartLock Surf software The SmartLock control panel stores all cardholder data in non volatile memory to ensure continued operation and security in the event that communications are lost to t...

Страница 5: ...ector cone connector Splice the thicker cable to a cable that is the appropriate thickness and then run the thinner cable to the terminal strip on the control panel Use Splices for Parallel Wiring The...

Страница 6: ...ons Cable multi drop configuration RS 485 Cable 22 AWG Stranded Shielded Twisted Pair 609 m 2000 ft max total length Belden 88761 or equivalent On Board Outputs Lock Control Form C Rated 30 VDC 1A Doo...

Страница 7: ...erall shield 152 m 500 ft max total length iButton Readers 6 conductors 22 AWG shielded or unshielded 15 m 50 ft max total length Dimensions Weight Controller Board 84 mm l x 65 mm w 3 5 16 l x 2 9 16...

Страница 8: ...5 The Door Contact Input should be bypassed if not used by using a jumper wire across the input or setting the switch to ignore the input Refer to the Door Contact Bypass Switch Setting 6 This contro...

Страница 9: ...iefly flickers when valid Wiegand data is received from the reader If Wiegand data is not valid or not supported this LED will stay OFF until the next valid card is read 3 The communication LED will f...

Страница 10: ...2 3 4 ON RS 485 DIPSWITCH SETTINGS TO USB PORT CABLE SUPPLIED SHIELD B A GND GND 12 VDC SMARTLOCK CONTROLLER 2 ON 8 1 5V 12V N O N C OFF N C N C N O N O Each Smartlock controller must have a unique a...

Страница 11: ...SmartLock Controller Page 11 of 26 Installation Manual Nov 2018 Rev 3 2 CANLAN NETWORK COMMUNICATIONS DEVICE NOTE The EIA RS 485 standard does not permit T Tap or Star connections...

Страница 12: ...SmartLock Controller Page 12 of 26 Installation Manual Nov 2018 Rev 3 2 AIR 485 COMMUNICATIONS DEVICE NOTE The EIA RS 485 standard does not permit T Tap or Star connections...

Страница 13: ...oller verify that the reader voltage jumper is set correctly for the reader being connected Connecting a 5 V reader to a 12 V power supply will damage the reader NOTE The SmartLock controller supports...

Страница 14: ...n Manual Nov 2018 Rev 3 2 iBUTTON READER NOTE Exit reader not supported with SmartLock iButton readers NOTE If using the SmartLock Connect Programming Module with iButton readers connect the programmi...

Страница 15: ...Controller Page 15 of 26 Installation Manual Nov 2018 Rev 3 2 Lock Output Relay Wiring DC ELECTRIC STRIKES NOTE Use 1N400x series diode as shown to prevent back EMF from damaging the controller 500 m...

Страница 16: ...and surge protection Check the maglock specifications for details 500 mA 500 mA IMPORTANT In some jurisdictions the use of a UL approved power supply and connection to the fire alarm system for emerge...

Страница 17: ...jurisdictions the use of a UL approved power supply and connection to the fire alarm system for emergency release may be required Installers should contact the local authority having jurisdiction to v...

Страница 18: ...ontact input Otherwise the door will be in alarm condition NOTE Exit Button requires momentary closure to activate relay Door Contact is used for forced entry and door held open annunciation and also...

Страница 19: ...omentary closure to activate relay 1 2 3 4 5 6 7 8 ON OFF ON 8 1 5V 12V N O N C N O N O N C N C SET RELAY CONTACTS N O N C LOCK DOOR OPER FORCED DHO RELAY LEDS TURN ON ACTIVATION RED DOOR OPERATOR OUT...

Страница 20: ...ch is used to erase the controller s memory and run diagnostics to set the baud rate to enable or bypass the door contact input to set the controller address from 1 to 30 LOCATION 1 2 3 4 5 6 7 8 ON W...

Страница 21: ...ed Relay outputs can be verified during this stage NOTE If the relays do not cycle ON OFF there may be a problem with the unit 5 Continue to set controller address and door contact bypass switch setti...

Страница 22: ...N RIGHT on diagram NOTE If door contacts are not installed but door contacts are enabled on the control panel via switch 8 unlock schedules will fail to take effect WIEGAND DATA LED COMMS LED 5V 12V N...

Страница 23: ...r is disconnected then reconnected ADDRESS SW 1 SW 2 SW 3 SW 4 SW 5 SW 6 1 OFF ON ON ON ON ON 2 ON OFF ON ON ON ON 3 OFF OFF ON ON ON ON 4 ON ON OFF ON ON ON 5 OFF ON OFF ON ON ON 6 ON OFF OFF ON ON O...

Страница 24: ...OFF ON 22 ON OFF OFF ON OFF ON 23 OFF OFF OFF ON OFF ON 24 ON ON ON OFF OFF ON 25 OFF ON ON OFF OFF ON 26 ON OFF ON OFF OFF ON 27 OFF OFF ON OFF OFF ON 28 ON ON OFF OFF OFF ON 29 OFF ON OFF OFF OFF O...

Страница 25: ...ed shielded cable 2000 ft MAX total length 609 m open the CLA50 and change the jumper settings or DIP switch settings DO NOT NOTES ADDRESS 1 SHOWN Dipswitch 1 is OFF GND B A 12 VDC PLUG IN TRANSFORMER...

Страница 26: ...2018 Rev 3 2 CLAUSB2 COMMUNICATIONS WIRING SmartLock is a registered trademark of Cansec Systems Ltd iButton is a registered trademark of Maxim Integrated Products Inc NOTE The EIA RS 485 standard doe...