background image

Network Camera

 Installation Guide

Please be sure to read the “Safety Precautions” section for correct use. After reading this 
Installation Guide, keep it in a readily accessible location for future reference. 

* Some cameras are not available in certain countries or regions.

Caution

   

Request a professional installer for all installation work. Never try to install the 
camera yourself. Doing so may result in unforeseen accidents such as dropping 
the camera or electric shock.

Check Included Items

Camera, Screws (M4) x 4  

Template 

Installation Guide (This document)

Setup CD-ROM 

Warranty Card 

Dedicated wrench

Safety Wire, Screws (M4) x 2 

Ceiling Plate 

RJ45 Coupler

LAN Cable Cap 

Packing Attachment 

Waterproof Packing

Zip Tie 

GND Screw (M3) x 1 

Multi-Cable

Waterproofing Tape 

Waterproofing explanation sheet

Accessories

The following accessories can be purchased separately as necessary. Some accessories are not 
available in certain countries or regions.

Pendant Mounting Kit PC640-VB

Dedicated accessory used to install the camera to the end of pipe that extends from high ceilings, 
such as in big-box stores.

Dome Unit DU640-S-VB

Smoked dome cover.

Sunshade Cover SC640-VB

Dedicated accessory to protect the camera body from direct sunlight.

Heater Unit HU641-VB

Dedicated accessory attached to the interior to maintain operation temperature within the dome 
and achieve stable operation even in extremely cold environments.

Canon AC Adapter PA-V18 

Dedicated AC adapter for this camera.

Safety Precautions

Installation Precautions

 

Warning   

Failure to follow the instructions may result in death or serious injury.

Do not install in the following places:

 

•  Places in strong direct sunlight, near heat-generating objects, or locations subject to 

high temperatures 

•  Places near fire sources or flammable solvents (alcohol, thinner, fuel, etc.) 
•  Places subject to oily smoke or steam 
•  Confined or enclosed places

Failure to do so may result in fire or electric shock.

•  Insulate the ends of cables you are not using.

Failure to insulate may result in fire or electric shock.

Notes on Power Supply

•  Only use the dedicated AC adapter (sold separately) for AC power.
•  Do not set any heavy objects on the power cable (or the LAN cable for a PoE power supply).
•  Do not pull, forcibly bend, scratch, or modify the power cable (or the LAN cable for a 

PoE power supply). 

•  Do not cover or wrap the AC adapter (sold separately) with cloth or blankets.

Failure to do so may result in fire or electric shock.

 

Caution   

Failure to follow the instructions may result in injury.

For installation or inspection of this camera, consult the dealer where you purchased 

the product.

 

•  This installation should be made by a qualified service person and should conform to 

all local codes. 

•  When installing, make sure the surface is capable of withstanding the total weight of the 

camera and accessories, and sufficiently reinforce if necessary.

•  Be sure to use installation screws designed for the type of surface the camera is to be 

installed.

•  Periodically check the parts and screws for rust and loosening, in order to prevent 

injuries and equipment damage due to falling items.

•  Do not install in unstable places, places subject to significant vibration or impact, or 

places subject to salt damage or corrosive gas.

•  Do not install in places subject to strong winds.
•  Do not install where snow can accumulate directly on the camera.
•  Be sure to attach the safety wire when installing the camera.

Failure to do so may result in the camera falling or other accidents.

•  Do not touch the edges of metal parts with bare hands.
•  Be careful not to get your fingers caught when installing.

Failure to do so may result in injuries.

BIE-7175-000

Caution   

Failure to follow the instructions may result in property damage. 

•  Do not move the lens unit by hand.
•  Do not install on an unstable surface.
•  To maximize shock resistant specifications, do not install on insufficiently strong 

surfaces or surfaces subject to significant vibration.

•  After turning off the power, do not turn the power on again for at least five seconds.
•  Take measures to remove static electricity before performing any procedures.
•  If there is condensation, please wait to power on, until the condensation dissipates.
•  Please waterproof and dust-proof camera, when installing outdoors.

Failure to do so may result in malfunctions.

•  Take care not to damage wiring or piping.

Failure to do so may result in damage to peripheral items.

 Important

We recommend the installation of a lightning arrester (a surge protection device) as a measure against 
failures caused by lightning strikes. Please refer to our website for details.

Precautions for Installing the Camera Outdoor

When installing the camera outdoors, observe the following 
precautions to retain waterproof/dustproof capabilities.

.

•  Use the sunshade cover (sold separately) when installing in a location 

with direct sunlight.

•  Completely wrap the cable connections and the ends of cables you 

are not using, including the connectors, with waterproof tape up to 
the cable jacket, so as not to allow water to enter. Please refer to 
the waterproofing explanation sheet for details on how to wrap the 
waterproofing tape.

•  When mounting the camera onto a wall or other upright surface, make 

sure that the cables and composite pipe are facing down to prevent 
rain infiltration.

•  If wiring the camera through the wiring hole on the bottom, use 

silicone sealant or a rubber mat to ensure waterproofing. Also use an 
insect repellent sponge if necessary.

•  Firmly fix the dome case to the main unit of the camera with the lock screws, taking care not to 

pinch cables between the main unit and dome case.

Precautions for Use

 

Warning   

Failure to follow the instructions may result in death or serious injury.

•  If you discover defective conditions such as smoke, strange sounds, heat or strange 

odors, immediately stop using the camera and contact your nearest dealer.

Fire or electric shock may result from continued use of the product.

•  If thunder starts, stop installation or inspection etc. and do not touch the camera or 

continue connecting the cable.

•  Do not disassemble or modify the camera.
•  Do not damage the connecting cable.
•  Do not insert foreign objects such as water or metal into the camera.
•  Do not use flammable sprays near the camera.
•  Do not leave LAN cables, external power supply, or the power connector for the AC 

adapter (

sold separately

) connected when the camera is not in use for long periods.

•  Do not use flammable solvents such as alcohol, paint thinner or benzine when cleaning 

the camera.

Failure to do so may result in fire or electric shock.

Specifications

Please refer to the Appendix – Specifications for specifications not listed below.

Lens 

2.4x optical zoom (4x digital zoom) lens (electric drive)

Viewing Angle 

For 16:9 aspect ratios

   

   Horizontal: 122.1° (W) – 50.1° (T) 

Vertical: 65.8° (W) – 28.2° (T)

   

For 4:3 aspect ratios

   

   Horizontal: 89.2° (W) – 37.6° (T) 

Vertical: 65.8° (W) – 28.2° (T)

Pan Angle Range 

350° (±175°)

Tilt Angle Range 

150° (±75°)

Rotation Angle Range  350° (±175°)
Network Terminal 

LAN x 1 (RJ45, 100Base-TX (auto/full-duplex/half-duplex))

   

– Use a category 5 or better LAN cable, 100 m (328 ft.) or less in length.

Audio Input Terminal 

 3.5 mm (  0.14 in.) mini-jack connector (monaural)

(common for LINE IN & MIC IN)
Audio Output Terminal   3.5 mm ( 0.14 in.) mini-jack connector (monaural)
(LINE OUT)
External Device I/O Terminal  Input x 2, Output x 2
Memory Card 

microSD Memory Card, microSDHC Memory Card, microSDXC Memory Card Compatible. 

Operating Environment  Temperature: 
   

   When the heater unit (sold separately) is installed

   

   Operating Temperature Range:

   

      AC: -40°C – +55°C (-40°F – +131°F) 
   Start-up Temperature Range:

   

      AC: -30°C – +55°C (-22°F – +131°F)

   

   – Sunshade cover (sold separately) necessary when under direct sun exposure

   

   When the heater unit (sold separately) is not installed

   

      AC, DC, PoE: -10°C – +55°C (+14°F – +131°F)

   

   – Sunshade cover (sold separately) necessary when under direct sun exposure

   

Humidity: 5% – 85% (without condensation)

Storage Environment 

Temperature: -30°C – +60°C (-22°F – +140°F)  
Humidity: 5% – 90% (without condensation)

Installation Method 

Ceiling mount/Surface mount

Power Supply 

PoE: PoE power supply via LAN connector (IEEE802.3at Type1 compliant)

   

AC Adapter: PA-V18 (100 – 240 V AC) (sold separately)

   

External power source: 24 V AC/12 V DC

Power Consumption 

PoE: Max. approx. 8.9 W*

1

   

AC Adapter PA-V18: Max. approx. 10.2 W (100 V AC)

   

 

Max. approx. 10.4 W (240 V AC)

   

DC: Max. approx. 9.3 W

   

AC: Max. approx. 8.7 W

   

 

Max. approx. 21.7 W*

2

   

*

1

 Class 0 power sourcing equipment (requests 15.4 W)

   

*

2

 When the heater unit (sold separately) is installed

ENGLISH