background image

ENG

Instructions

Содержание RF 35mm F1.8 MACRO IS STM

Страница 1: ...ENG Instructions ...

Страница 2: ...tepping Motor Camera Firmware Please use the latest version of firmware with the camera in use For details on whether the firmware is the latest version or not and for details on updating the firmware please check the Canon website Conventions used in these instructions Warning to prevent lens or camera malfunction or damage Supplementary notes on using the lens and taking pictures ...

Страница 3: ... of sight z z Do not leave a lens in the sun without the lens cap attached The lens may concentrate entering sunlight and cause a malfunction or fire Caution Details pertaining to risks that may result in injury z z Do not leave the product in places exposed to extremely high or low temperatures The product may cause burns or injury when touched Caution Details pertaining to risks that may result ...

Страница 4: ...om a warm environment into a cold one z z Please also read any lens related handling precautions listed in your camera s instruction manual Shooting Precautions When the camera recovers from the auto power off status to the standby status the front end of the lens moves in both AF MF mode and an initial reset is performed on the focus lens z z Do not shoot until the initial reset is completed z z ...

Страница 5: ...against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio ...

Страница 6: ...cusing ring 7 Contacts 6 Image stabilizer switch 9 Hood mount 13 Lens mount index 6 Focus mode switch 7 Lens mount 6 Macro Ring Lite Macro Twin Lite mount 15 z z For detailed information reference page numbers are provided in parentheses Nomenclature ...

Страница 7: ...m the camera z z When the power switch of the camera is set to OFF the focus lens pushed forward is automatically stored Do not detach the lens until the lens is completely stored z z After detaching the lens place the lens with the rear end up and attach the dust cap to prevent the lens surface and contacts from getting scratched Make sure the lens and dust cap mount indexes are aligned when atta...

Страница 8: ...rding to the variation in the air temperature and posture z z Do not touch the operating part in the front of the lens while the focus lens is operating If external pressure is applied to the moving part the lens initialization may be performed to return the focus lens to the correct position for control purposes z z The lens focusing ring is electronic z z When AF operation is set to ONE SHOT man...

Страница 9: ...action of the control ring allows you to have a sense of how much it is being turned Please refer to the camera s instructions for details on how to use the control ring z z There are cases in which the sound of control ring operations may be recorded when shooting movies z z The clicking sensation of the control ring can be removed by the Canon Service Center chargeable ...

Страница 10: ...bject that moved z z The Image Stabilizer may not be fully effective if you shoot from a violently shaking vehicle or other transportation z z When using a tripod it is recommended that you set the image stabilizer switch to OFF z z Even with a monopod the Image Stabilizer will be as effective as during hand held shooting However depending on the shooting conditions there are cases in which the Im...

Страница 11: ...tions z z In semi darkened areas such as indoors or outdoors at night z z In locations where a flash cannot be used such as art museums and theater stages z z In situations where your footing is uncertain z z In situations where fast shutter speed settings cannot be used z z Panning shots of vehicles trains etc ...

Страница 12: ...he following during close up macro shooting Camera shake creates more impact than on normal shots and the effects of the image stabilizing function are reduced Depth of field becomes extremely shallow when taking close up macros shots and the focus may blur if the camera is moved forward or backward z z The minimum focusing distance minimum distance between the subject and the imaging area is 0 17...

Страница 13: ... macro shooting the change in the effective f number is more than negligible When deciding the exposure using a hand held exposure meter apply the following exposure factor Magnification 1 5 1 3 1 2 Focusing distance m ft 0 27 0 89 0 20 0 66 0 17 0 56 Effective f No 2 1 2 2 2 4 Exposure factor stops 1 3 2 3 1 1 2 1 2 1 Upper values 1 3 stops Lower values 1 2 stops z z Conditions of the subject are...

Страница 14: ...of the picture may occur z z Turn OFF the power of the camera before attaching or detaching the hood 7 Hood Sold separately 8 Filters Sold separately You can attach filters to the filter mounting thread on the front end of the lens or on the front end of the hood z z Only one filter may be attached z z If you need a polarizing filter use the Canon Circular Polarizing Filter PL C B z z Turn OFF the...

Страница 15: ...nses Sold separately Attaching a 250D 500D Close up Lens enables close up photography It provides the following magnifications z z 250D 0 14 to 0 62x z z 500D 0 07 to 0 56x z z MF mode is recommended for accurate focusing ...

Страница 16: ...ilter or causes the lens to fail z z For how to use the MR 14EX II and MT 26EX RT please refer to the lite s instructions When the MR 14EX II is in use Effective Flash Range Reference Aperture Magnification Focusing distance m ft Effective flash range both sides firing 22 16 11 8 5 6 4 2 8 2 1 8 1 5 1 3 1 2 0 27 0 89 0 20 0 66 ISO100 ISO400 0 17 0 56 1 5 1 3 1 2 0 27 0 89 0 20 0 66 0 17 0 56 22 16...

Страница 17: ...Diameter and Length 74 4 x 62 8 mm 2 93 x 2 47 in Weight Approx 305 g 10 76 oz Hood EW 52 Sold separately Lens Cap E 52 II Case LP1016 Sold separately z z The lens length is measured from the lens mount surface to the front end of the lens Add 23 9 mm 0 94 in when including the lens cap and dust cap z z The maximum diameter length and weight listed are for the lens itself only z z All data listed ...

Страница 18: ...CT1 D072 A 0818Ni CANON INC 2018 ...