2-3
2
■
COUNTER
title
Use case
Details
Service mode
Adjustment range
Unit
Default value
Inlet static charge eliminator
counter
A point in time of the consumption
degree confirmation / exchange
of the
inlet static charge
eliminator
.
To clear the counter value: Select the item, and then press
Clear key.
To change the estimated life: Select the item, enter the value,
and then press OK key.
(LV1)
COPIER>COUNTER>DRBL-2
>ENT-STC
0 to 99999999
time
0
Delivery static charge
eliminator counter
A point in time of the consumption
degree confirmation / exchange
of the
delivery static charge
eliminator.
To clear the counter value: Select the item, and then press
Clear key.
To change the estimated life: Select the item, enter the value,
and then press OK key.
(LV1)
COPIER>COUNTER>DRBL-2
>DL-STC
0 to 99999999
time
0
Shift roller counter
A point in time of the consumption
degree confirmation / exchange
of the shift roller.
1st line: Total counter value from the previous replacement.
2nd line: Estimated life.
To clear the counter value: Select the item, and then press
Clear key.
To change the estimated life: Select the item, enter the value,
and then press OK key.
(LV1)
COPIER>COUNTER>DRBL-2
>OFST-RL
0 to 99999999
piece
0
Staple unit counter
A point in time of the consumption
degree confirmation / exchange
of the staple unit.
1st line: Total counter value from the previous replacement.
2nd line: Estimated life.
To clear the counter value: Select the item, and then press
Clear key.
To change the estimated life: Select the item, enter the value,
and then press OK key.
(LV1)
COPIER>COUNTER>DRBL-2
>FIN-STPR
0 to 99999999
time
0
Punch unit counter
A point in time of the consumption
degree confirmation / exchange
of the punch unit.
To clear the counter value: Select the item, and then press
Clear key.
To change the estimated life: Select the item, enter the value,
and then press OK key.
(LV1)
COPIER>COUNTER>DRBL-2
>PUNCH
0 to 99999999
time
0
■
FUNCTION SETTING
title
Use case
Details
Service mode
Adjustment
range
Unit
Default value
Controller PCB RAM clear
A point in time of the
initialization of the EEPROM.
To execute the RAM clear of Finisher Controller PCB to delete all the
adjustment contents and counter information.
-
-
-
-
T-2-2
T-2-3
Содержание Perfect Binder D1
Страница 1: ...5 4 3 2 1 Inner Finisher D1 Inner Finisher Additional Tray A1 Service Manual Digest Rev0...
Страница 4: ...0 0 4...
Страница 6: ...Safety Precautions Notes Before it Works Serving...
Страница 8: ...1 1 Periodic Servicing Periodic Service Works Finisher...
Страница 10: ...2 2 Adjustment Basic Adjustment Adjustment at Time of Parts Replacement finisher...
Страница 14: ...3 3 Parts Placement Diagram List of Parts Finisher...
Страница 25: ...5 5 General Circuit Diagram Service Tools General Circuit Diagram Finisher...