3
3
3-4
3-4
Periodical Services > Cleaning > Cleaning at Service Visit > Fixing unit
Periodical Services > Cleaning > Cleaning at Service Visit > Fixing unit
Clean the ADF scanning area (on the left side of the platen glass (A)) with a cloth dampened
with water. Then wipe the area with a soft, dry cloth.
A
Fixing unit
MEMO:
Cleaning the Fixing Unit takes approximately 150 seconds.
1. Press [Menu] key.
2. Press [ - ] key or [ + ] key to select <ADJUST./CLEANING>, then press [OK].
3. Press [ - ] key or [ + ] key to select <FIX. UNIT CLEANING>, then press [OK].
4. Press [ - ] key or [ + ] key to select <CLEAN PAPER PRT>, then press [OK].
MEMO:
Make sure that LTR paper is loaded in a paper source.
5. Press [ - ] key to select [YES].
The cleaning page is printed.
■
F-3-4
F-3-4
6. Load the cleaning page in the multipurpose tray with the printed side facing down.
7. Perform from step 1 to step 3 again.
8. Press [ - ] key or [ + ] key to select <START CLEANING>, then press [OK].
9. Press [ - ] key to select [YES].
Cleaning starts. When finished, the display returns to the standby mode.
F-3-5
F-3-5