Technology > Embedded RDS > E-RDS Setup > Steps to E-RDS settings
Technology > Embedded RDS > E-RDS Setup > Steps to E-RDS settings
(3) Network settings
Based on the results of the information obtained in (2) Advance preparations, make the
device network related settings.
See Users’ Guide for detailed procedures.
CAUTION:
Ensure to reboot the device when any change is added to the network setting.
■
E-RDS setting items (service mode)
Item
Description
E-RDS SWITCH
(NETWORK GR. > E-RDS)
Set use/ no use of Embedded-RDS function
Off: Function not used / On: Function used
e-Maintenance/ imageWARE Remote system to send
device information, counter data, error statuses to the
UGW.
Default : Off (Function not used)
RGW-ADDRESS
(NETWORK GR. > E-RDS)
URL setting of UGW
Max 128 characters
Default : https://a01.ugwdevice.net/ugw/agentif01
RGW-PORT
(NETWORK GR. > E-RDS)
Set port number of UGW
Validation : 1 to 65535
Default : 443
COM-TEST
(NETWORK GR. > E-RDS)
Execution of a communication test with UGW / Display of
the result
Perform Communication test with UGW and set "Done." or
"Could not execute." as the result.
COM-LOG
(NETWORK GR. > E-RDS)
Display of detailed information about a communication error
with UGW
Error information of a connection failure with UGW is
displayed.
Error occurrence date and time, error code, and detailed
error information are displayed.
Max 5 latest loggings retained
Max 128 characters for Error information.
CLEAR
(NETWORK GR. > E-RDS)
Initialization of E-RDS SRAM data
SRAM data of E-RDS is initialized and returned to the
factory setting value at shipment.
CLEAR
(NETWORK GR. > CA-KEY)
Initialization of CA certificate
When the power is turned OFF/ ON after execution, the CA
certificate in the factory setting is automatically installed.
T-2-21
■
Steps to E-RDS settings
1. Start [Service Mode].
2. Select [NETWORK GR.] and press [OK] or [ ] button to go to the network setting menu.
SERVICE MODE
NETWORK GR.
LOG GR.
PANEL LOCK GR.
F/W UPDATE GR.
3. Select [E-RDS] and press [OK] or [ ] button to go to E-RDS setting menu.
NETWORK GR.
E-RDS
FTP SYSLOG
JOB SERIALIZE
BUFFER LIMIT
4. Select [CLEAR] and press [OK] or [ ] button to display Confirm Initialization screen.
Select [Yes] and press [OK] button.
NOTE:
This operation initializes the E-RDS settings to factory setting values.
For the setting values to be initialized, see the section of “Initializing E-RDS settings”.
E-RDS
CLEAR
RGW-PORT
COM-TEST
COM-LOG
Excute?
No
Yes
Initializing...
Done.
F-2-129
F-2-130
F-2-131