Network Port Settings
The default port of the HTTP server used for MEAP and MEAP applications to provide the
servlet function is 8000, and the HTTPS server's default port is 8443. In the case that these
ports have already used by the customer who is to introduce this application, the MEAP
application cannot use the HTTP (or HTTPS) server(s).
By changing the following ports to use, however, the MEAP application can be used as well
as the existing system.
The procedure for setting the HTTP/HTTPS server port is shown below.
1) Start service mode. From the [ Setup ] menu, select [ SERVICE MODE ] > [ FUNCTION
GR. ] > [ MEAP ].
Setup
PS
MEAP Settings
Check
Counter
SERVICE MODE
SERVICE MODE
ADJUST GR.
OPTION GR.
FUNCTION GR.
LOG GR.
FUNCTION GR.
COLOR MODE SLCT
MEAP
DDNSINTY
IPMT
U
2) To set up the HTTP server port, select [ MEAP-PN ]. To set up the HTTPS server port, select [
MEAP-SSL ]. When the port number setting screen appears, specify a port number. Use
the Up and Down keys to specify the setting.
MEAP-SSL
8443
(0-65535)
MEAP
MEAP-PN
MEAP-SSL
CDS-MEAP
CDS-FIRM
F-2-49
F-2-50
F-2-51
Note:
A port number can be any integer from 0 to 65535. To avoid port numbers that are
frequently used, do not use any integer from 0 to 1023.
Server
Setting value
Default value / Value after RAM clear
HTTP Server
1024 to 65535
8000
HTTPS Server
1024 to 65535
8443
Note:
If PS Print Server Unit is connected, do not specify port 8080.
If port 8080 is specified, the RUI of the device where the MEAP authentication
application is running cannot be displayed. (Port 8080 is reserved to allow the PS Print
Server Unit to redirect to the iR device.)
3) Restart the device if the port number is set.
■
How to Check the Serial Number
When performing MEAP device support, the serial number of the device is necessary in some
cases.
Examples of where the serial number is necessary
• When initializing SMS login password (obtaining a switch license)
• When obtaining a MEAP application license from LMS
• When obtaining a transfer license of MEAP application
• When obtaining a special license for reinstalling MEAP application
If a problem occurs in the MEAP device and you want to contact the support department of
the sales company, you need to provide the serial number. Perform the following procedure to
get the serial number.
T-2-13