0017-6037
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
T-3-1
Display
Code
Detail Code
Main Cause/Symptom
Countermeasure
E000
0000
Startup error
The temperature detected by the main or sub thermistor does
not rise to the specified value during startup control.
- Check the fixing film connector.
- Replace the fixing film unit.
- Replace the DC controller PCB.
E001
0000
Abnormally high temperature (detected by main thermistor)
The main thermistor detected an abnormally high temperature
(240 deg C) during temperature control.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
0001
Abnormally high temperature (detected by sub thermistor)
The sub thermistor detected an abnormally high temperature
(295 deg C) during temperature control.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
E002
0000
Low temperature during temperature control.
The target temperature is not reached during temperature
control.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
E003
0000
Abnormally low temperature (detected by main thermistor)
After the temperature detected by the main thermistor has
reached the specified value, it does not reach the specified value
during initial rotation.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
0001
Abnormally low temperature (detected by sub thermistor)
After the temperature detected by the sub thermistor has
reached the specified value, it does not reach the specified value
during initial rotation.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
E007
0000
Fixing film sensor failure
The fixing film sensor is faulty.
- Check the connector of the fixing film sensor.
- Replace the fixing film sensor.
- Replace the DC controller PCB.
E010
0000
Main motor failure
The main motor is faulty.
- Check the connector of the main motor.
- Replace the main motor.
- Replace the DC controller PCB.
E019
0000
Waste toner full detection
The waste toner full state was detected.
Replace the drum unit.
0001
Waster toner full detection sensor is faulty.
The waste toner full state was detected continuously for five or
more seconds while the main motor was turning.
- Check the connector of the waster toner full sensor.
- Replace the waste toner full sensor.
- Replace the DC controller PCB.
E052
0000
Erroneous connection to duplex unit
Disconnection of the duplex unit was detected after power-on,
detection of normal connection to the duplex unit, and start of
communication.
- Check the connectors of the duplex unit and DC controller PCB.
- Replace the duplex controller PCB.
- Replace the DC controller PCB.
E100
0000
BD detection PCB failure
The BD detection PCB is faulty.
- Check the connector of the BD detection PCB.
- Replace the laser scanner unit.
- Replace the DC controller PCB.
Содержание iR2018 Series
Страница 1: ...Aug 8 2007 Portable Manual iR2030 2025 2022 2018 Series ...
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 17: ...Chapter 2 5 ...
Страница 18: ......
Страница 24: ...Chapter 3 12 ...
Страница 80: ......
Страница 91: ...F 6 11 F 6 12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 ...
Страница 106: ...Chapter 7 93 ...
Страница 109: ...Chapter 7 96 ...
Страница 110: ...T 7 2 ...
Страница 113: ......
Страница 114: ...T 7 3 ...
Страница 120: ......
Страница 121: ...Aug 8 2007 ...
Страница 122: ......