Canon
imageRUNNER ADVANCE C9000S PRO Series Service Guide
VII.
Servicing Notes
A. Power and Plug Requirements
Canon USA Inc. strongly suggests dedicated and properly grounded outlets
for these imageRUNNER ADVANCE devices and optional accessories.
Before installation, confirm that dedicated NEMA receptacles are available for
these devices.
The imageRUNNER ADVANCE C9000S PRO Series requires a dedicated
single-phase 208V/15A NEMA 6-15R receptacle for the Main Unit and a
dedicated single-phase 120V/20A NEMA 5-20R receptacle for the
PRISMAsyunc controller and accessories for proper operation.
Confirm that a single-phase 120V/20A NEMA 6-15R and a single-phase
120V/20A NEMA 5-20R receptacles are available prior to installation.
Power and Plug Requirements for Main Unit and Accessories (Table 4)
Description
Power Supply
Plug
Specifications
imageRUNNER ADVANCE C9000S PRO Series
208V/15A
NEMA 6-15
Paper Deck Unit-A1
From the Main Unit
N/A
POD Deck Lite-A1
120V/15A
NEMA 5-15
Multi Drawer Paper Deck-A1
Document Insertion Unit-H1
Paper Folding Unit-G1
Professional Puncher-C1 (With Integration Unit)
PRISMAsync Controller
Staple Finisher-A1
Booklet Finisher-A1
Inner Booklet Trimmer-A1
From the Finisher
N/A
Puncher Unit-BF1
imageRUNNER ADVANCE C9000S PRO Series Service Guide
March 2015
Revision 2
Page 23
Содержание imageRUNNER ADVANCE C9065S PRO
Страница 1: ...Canon Service Guide ...