4
4
4-186
4-186
Parts Replacement and Cleaning > Pickup Feed System > Removing the Duplex Unit > Procedure
Parts Replacement and Cleaning > Pickup Feed System > Removing the Duplex Unit > Procedure
Removing the Duplex Unit
■
Preparations
1) Open the Right Lower Cover and Right Upper Cover.(Refer to page 4-175)
■
Procedure
1) Remove the Front Cover of Right Unit.
• 1 screw
• 1 claw
Claw
2) Remove the connector and the grounding wire.
• 1 screw
• 1 wire saddle
• 2 connectors
Connectors
Wire saddle
Grounding wire
x
2
F-4-354
F-4-355
3) Hold the sides of Duplex Unit and remove it.
CAUTION:
When removing the Duplex Unit, note that the Right Door Rotation Hinge and the spring
are easily disassembled.
Right door
rotation hinge
Spring
F-4-357
F-4-356