Parts Replacement and Cleaning > Image Formation System > Removing the ITB Cleaning Unit > Actions after Replacement
Parts Replacement and Cleaning > Image Formation System > Removing the ITB Cleaning Unit > Actions after Replacement
Removing the ITB Cleaning Unit
■
Preparations
1) Open the Front Cover, Right Lower Cover and Right Upper Cover.
2) Remove the ITB Cover.
3) Remove the ITB Unit.
■
Procedure
CAUTION:
When removing/installing it, do not contact the ITB Cleaning Unit to the ITB.
1) Hold the left and right grip and remove the ITB Cleaning Unit in the direction of the arrow.
• 2 screws
x2
F-4-121
2) Place the removed ITB Cleaning Unit on the paper.
■
Actions after Replacement
1) To execute the ITB Equilibrium Position Detection, make the main body in standby state.
2) Execute the ITB Equilibrium Position Detection Service Mode (COPIER>FUNCTION>MISC-
P>ITB-INIT) (Level 1). This service mode will take approx. 2 to 3 minutes.
F-4-122