■ Control Description
In horizontal scanning direction, sensor level of each original detection position is measured by moving the Scanner Unit to the
detection position shown in the figure in relation to the original setting position. The size in the vertical scanning direction is
determined by using the Original Size Sensor (AB) and Original Size Sensor (Inch).
LTRR
STMT
LTR
LGL
279.4×431.8mm
(11"×17")
Original Size Sensor (Inch)
Inch type
STMTR
CCD original detection position
Original detection
position 1
Original detection
position 2
Original detection
position 3
Original Size Sensor (AB)
B5
A5
A4
B5R
A4R
A5R
B4
A3
K8
K16
AB type
CCD original detection position
Original detection
position 1
Original detection
position 2
Original detection
position 3
Original detection
position 4
Original detection position 5
Original detection position 6
Dust Detection Control
■ Overview
When reading an original, original reading position is changed according to the presence/absence of dust on the Stream Reading
Glass or the Guide Plate of the ADF (on the Platen Roller in case of the reverse model), or image correction is performed to
prevent the dust to be printed on an image. This control is performed only when the ADF is being used and has been closed.
Control timing
Dust evasion control
• At job completion
• At the start of a job (only when one of the following conditions is met)
• At the start of the first job after power ON or recovery from sleep mode
• At the start of the first job after a message prompting cleaning of dust is displayed and then the ADF is opened and then
closed
• At the start of a job when dust evasion control performed at the end of the previous job failed to finish normally
Image correction control
• At paper interval (after each sheet is read)
Main power
switch ON
Start key
ON
Dust detection
control
STBY
WMUP
1st
SCAN
2nd
SCAN
Dust detection
control
Dust detection
control
Control description
Dust evasion control
• At job completion
The Reading Sensor detects presence/absence of dust at the reading position A, B, and C in that order, and the position
where dust is least present becomes the reading position for the next job.
• When a job starts
Like the time of completion of a job, presence/absence of dust is detected at all positions (A, B, and C in that order).
The position where dust is least present is used as the reading position and reading starts.
2. Technology
41
Содержание imageRUNNER ADVANCE C3500 III Series
Страница 1: ...Revision 2 1 imageRUNNER ADVANCE C3500 III Series Servie Manual ...
Страница 23: ...Safety Precautions Laser 2 Power Supply Lithium Battery 3 Toner Safety 4 Notes on works 4 ...
Страница 28: ...Product Overview 1 Product Lineup 7 Specifications 11 Parts Name 34 ...
Страница 153: ...Periodical Service 3 Consumable Parts List 132 Cleaning Parts 136 ...
Страница 158: ...Cleaning Parts 15 9 14 13 8 4 16 17 5 3 6 7 1 2 12 10 11 15 16 3 Periodical Service 136 ...
Страница 210: ... Procedure 1 Remove the 4 cables 4 Connectors 1 3 Wire Saddles 2 3x 4x 1 1 2 2 4 Parts Replacement and Cleaning 188 ...
Страница 211: ...2 Remove the HDD Unit 1 3 Hooks 2 1 Screw 3 1x 2 2 3 4 Parts Replacement and Cleaning 189 ...
Страница 249: ...2 3 1x 4 Parts Replacement and Cleaning 227 ...
Страница 293: ...Adjustment 5 Pickup Feed System 272 Document Exposure System 275 Actions after Replacement 277 ...
Страница 306: ...Troubleshooting 6 Initial Check 285 Test Print 286 Troubleshooting Items 291 Debug Log 304 ...
Страница 345: ...Error Jam Alarm 7 Outline 324 Error Code 328 Error Code FAX 466 Alarm Code 469 Jam Code 517 ...
Страница 949: ...COPIER Service mode for printer COUNTER Counter mode LIFE DF PR PD 1 For R D 8 Service Mode 927 ...
Страница 1010: ...Super G3 FAX Board AZ1 1147 Super G3 2nd Line Fax Board AU1 1154 Cassette Heater Unit 41 1167 9 Installation 988 ...
Страница 1018: ...5 Remove the cushioning material from the copyboard section Model without DADF Model with DADF 9 Installation 996 ...
Страница 1025: ...4 NOTE The removed cover will be used in step 6 5 2x 2x 6 NOTE Use the cover removed in step 4 9 Installation 1003 ...
Страница 1029: ...1 2 2x 3 4 NOTE The removed CR BOX Upper Unit will be used in step 14 9 Installation 1007 ...
Страница 1033: ...13 NOTE Usethe Base Small Cover removed in step 5 14 NOTE Use the CR BOX Upper Unit removed in step 4 15 9 Installation 1011 ...
Страница 1050: ...Installation Procedure Installing the Equipment 1 2 3 9 Installation 1028 ...
Страница 1052: ...8 Turn ON the main power switch 9 Installation 1030 ...
Страница 1055: ...3 4 CAUTION Be sure that the Inner 2 way Tray Support Member is installed properly 9 Installation 1033 ...
Страница 1063: ...2 2x 1x 3 1x 1x 1x 4 1x 1x NOTE The removed screw will be used in step 5 9 Installation 1041 ...
Страница 1065: ...6 CAUTION Be careful not to trap the cable when mounting the cover 1x 7 2x 9 Installation 1043 ...
Страница 1075: ... In the case of the Reversal DADF 1 2 3 NOTE The removed part will be used in step 8 9 Installation 1053 ...
Страница 1088: ...4 6x 5 4x 6 7 NOTE Do not close the Wire Saddle 1x 8 9 Installation 1066 ...
Страница 1090: ...12 NOTE Be sure to adjust the number of cushions according to the thickness of the Card Reader 13 9 Installation 1068 ...
Страница 1091: ...14 15 16 17 2x 18 9 Installation 1069 ...
Страница 1103: ...3 CAUTION Install the CC VI Cable in the direction shown in the figure 2x 1x Installing the Covers 1 1x 9 Installation 1081 ...
Страница 1104: ...2 2x 3 Connect the power plug to the outlet 4 Turn ON the power switch 9 Installation 1082 ...
Страница 1111: ...5 CAUTION To avoid damage do not pull the Utility Tray too much 6 2x 2x TP M4x8 Black 9 Installation 1089 ...
Страница 1112: ...When Installing the USB Keyboard 1 9 Installation 1090 ...
Страница 1114: ...Installation Procedure Removing the Covers 1 2x 2 1x 3 2x 9 Installation 1092 ...
Страница 1115: ... Installing the Removable HDD Kit 1 2 3x 4x 9 Installation 1093 ...
Страница 1119: ...11 12 1x 13 NOTE Use the screw removed in step 3 1x 9 Installation 1097 ...
Страница 1120: ...14 3x 4x Installing the Covers 1 2 2x 3 1x 9 Installation 1098 ...
Страница 1123: ...Installation Procedure Removing the Covers 1 2x 2 1x 3 2x 9 Installation 1101 ...
Страница 1124: ... Installing the 2 5inch 1TB HDD 1 3x 4x 2 1x NOTE The removed screws will be used in step 7 9 Installation 1102 ...
Страница 1127: ...8 3x 4x Installing the Covers 1 2x 2 1x 9 Installation 1105 ...
Страница 1134: ...2 On the screen shown below press Change and then Detailed Settings 3 9 Installation 1112 ...
Страница 1140: ...Installation procedure Remove the Control Panel 1 2 2x 3 4 2x 5 2x 9 Installation 1118 ...
Страница 1141: ...6 2x 7 4x 8 3x 9 10 9 Installation 1119 ...
Страница 1142: ...11 12 6x 13 2x 14 9 Installation 1120 ...
Страница 1143: ... Installing the NFC Kit 1 2 2x 3 1x TP M3x4 4 1x 9 Installation 1121 ...
Страница 1144: ... Installing the Control Panel 1 2 2x 3 6x 4 9 Installation 1122 ...
Страница 1145: ...5 6 3x 7 4x 8 2x 9 10 2x 9 Installation 1123 ...
Страница 1146: ...11 2x 12 13 2x 14 9 Installation 1124 ...
Страница 1154: ...14 4x Installing the Relay PCB 1 1x 1x TP M3x6 1x 2 1x 1x 9 Installation 1132 ...
Страница 1155: ...3 4 2x 3x 5 4x 6 9 Installation 1133 ...
Страница 1162: ... Installing the Relay PCB 1 1x 1x TP M3x6 1x 2 1x 1x 9 Installation 1140 ...
Страница 1163: ...3 4 2x 3x 5 4x 9 Installation 1141 ...
Страница 1166: ...1 CAUTION Do not insert the screwdriver into the hole when removing the cover 2 3 2x 9 Installation 1144 ...
Страница 1167: ...4 1x 5 CAUTION Be sure to install the Dehumidification switch in the correction direction 1x 9 Installation 1145 ...
Страница 1172: ... Installing the Covers 1 1x 2 NOTE Store the removed Face Cover in the Tray Guide in step 5 3 2x 4 9 Installation 1150 ...
Страница 1180: ...6 1x 7 8 5x M3x6 9 Installation 1158 ...
Страница 1192: ...5 CAUTION Be sure to release the lock and then disconnect the FCC Connector 1x 6 7 9 Installation 1170 ...
Страница 1193: ... Installing the Cassette Heater 1 2 3 In the case of Host machine TP Round End M3x6 1x 9 Installation 1171 ...
Страница 1200: ...2 3 2x 4 1x 9 Installation 1178 ...
Страница 1201: ...5 CAUTION Be sure to install the switch in the correction direction 1x 6 2x 9 Installation 1179 ...
Страница 1202: ...7 8 9 Connect the power plug of the host machine to the outlet 10 Turn ON the main power switch 9 Installation 1180 ...