Copier Color | iR-ADV C3330/C3325/C3320 Series |
Opening waste toner cover/ toner leakage due to the defect waste
toner case
[Symptom]
In the machines prior to the Countermeasure cut-in serial number in factory described below The following symptoms may occur
in the waste toner container
• The tape that fixes the upper and lower sections of the waste toner container is lifted, and the waste toner leaks from the
gap made by the lifted tape.
• When opening and closing the cassette 1, the waste toner container flies out and the waste toner cover opens.
[Cause]
The above-mentioned symptoms are caused by the following reasons
• Since the tape that is attached to the waste toner container is so stiff that the tape is lifted.
• Since only small part of the claw of the waste toner container is hooked, it flies out.
[Service work]
When the above-mentioned symptoms occur, replace the waste toner container with a new type (WT-202) (FM1-A606-030).
[Service parts]
No.
Part Number
Description
1
Old
FM1-A606-020
CONTAINER, WASTE TONER, WT-202
New
FM1-A606-030
CONTAINER, WASTE TONER, WT-202
[Countermeasure cut-in serial numbers in factory]
Model
Serial number
iR-ADV C3330 AS 230V
QTZ02079
iR-ADV C3325 AS 230V
QUB01173
iR-ADV C3320 AS 230V
QUC02780
iR-ADV C3330 CN 220V
QUE00822
iR-ADV C3325 CN 220V
QUF00958
iR-ADV C3320 CN 220V
QUG02246
iR-ADV C3320L CN 220V
QUH02434
iR-ADV C3330 CN 220V G
TYT00503
iR-ADV C3325 CN 220V G
TYV00502
iR-ADV C3320 CN 220V G
TYX00512
iR-ADV C3330i EUR 230V
QTF06129
iR-ADV C3325i EUR 230V
QTS11319
iR-ADV C3320i EUR 230V
QTT10023
iR-ADV C3320 EUR 230V
QTU00964
iR-ADV C3330 IND 230V
RJS00576
iR-ADV C3325 IND 230V
RJU00582
iR-ADV C3320 IND 230V
RJV01657
iR-ADV C3330 KR 220V
QUJ00852
iR-ADV C3325 KR 220V
QUK03506
iR-ADV C3320 KR 220V
QUL02000
iR-ADV C3330i LTN 230V
RJQ00722
iR-ADV C3325i LTN 230V
RJR00758
iR-ADV C3330 TW 120V
QUM00501
iR-ADV C3325 TW 120V
QUN00501
iR-ADV C3320 TW 120V
QUP00501
iR-ADV C3330i US 120V G
QTX00507
iR-ADV C3330i US 120V
QTV04753
77
Содержание imageRUNNER ADVANCE C3330 Series
Страница 1: ...Trouble Shooting Guide imageRUNNER ADVANCE C3330 Series August 2017 OIP Field Quality Assurance Div ...
Страница 83: ...iR ADV C3325i US 120V QTW07191 78 ...
Страница 85: ...iR ADV C3325i US 120V QTW07191 iR ADV C3330i US 120V G QTX00507 80 ...
Страница 90: ...1 8 Remove 4 screws 1 on the Tray 1 1 9 Remove 5 screws 1 on the undersurface of the Tray 1 85 ...
Страница 97: ...2 12 Remove 5 screws 1 on the undersurface of the Tray 1 2 13 Detach the Tray cover upper 1 92 ...
Страница 105: ...If the symptom does not improve check other causes 100 ...
Страница 124: ...4 Mount the left cover upper and then close the front cover 119 ...
Страница 130: ...7 Make a test copy and check that a jam does not occur If the symptom does not improve check other causes 125 ...
Страница 140: ...3 Remove the inner cover Screw 1 pc Claw 2 pcs 4 Replace the empty sensor lever 1 with the new type Claw 2 pcs 135 ...
Страница 144: ...139 ...
Страница 176: ...Inner Finisher_G1 EX QVA13172 171 ...
Страница 197: ...Inner Finisher G1 EX QVA10470 192 ...