Copier Color | iR-ADV C3330/C3325/C3320 Series |
The primary transfer roller drive coupling is coming off and
breaking due to interfering with the sheet metal of the main body
[Symptom]
Primary transfer roller drive coupling [1] may come off [A] or break [B] when removing the main drive assembly from the main
body.
[Cause]
The above symptom occurs because sheet metal of back of the main body and the primary transfer roller drive coupling interfere
with each other when removing the main drive assembly.
[Service work]
Follow the steps below when removing the main drive assembly.
Coupling set (FM1-M652-000) is newly set up as service part. It consists of the following components.
• Coupling [1]
• Compression spring [2]
1) Move the main drive assembly in a horizontal direction 10mm - 15mm so that the primary transfer roller drive coupling can be
removed from the main body.
2) Remove the main drive assembly by lifting the bottom.
3) If the primary transfer roller drive coupling comes off, insert the spring [2] into the gear [1] and attach the transfer coupling [3]
[A]. If the coupling is broken, prepare a coupling set (FM1-M652-000) and replace with a new coupling. It goes the same if the
73
Содержание imageRUNNER ADVANCE C3330 Series
Страница 1: ...Trouble Shooting Guide imageRUNNER ADVANCE C3330 Series August 2017 OIP Field Quality Assurance Div ...
Страница 83: ...iR ADV C3325i US 120V QTW07191 78 ...
Страница 85: ...iR ADV C3325i US 120V QTW07191 iR ADV C3330i US 120V G QTX00507 80 ...
Страница 90: ...1 8 Remove 4 screws 1 on the Tray 1 1 9 Remove 5 screws 1 on the undersurface of the Tray 1 85 ...
Страница 97: ...2 12 Remove 5 screws 1 on the undersurface of the Tray 1 2 13 Detach the Tray cover upper 1 92 ...
Страница 105: ...If the symptom does not improve check other causes 100 ...
Страница 124: ...4 Mount the left cover upper and then close the front cover 119 ...
Страница 130: ...7 Make a test copy and check that a jam does not occur If the symptom does not improve check other causes 125 ...
Страница 140: ...3 Remove the inner cover Screw 1 pc Claw 2 pcs 4 Replace the empty sensor lever 1 with the new type Claw 2 pcs 135 ...
Страница 144: ...139 ...
Страница 176: ...Inner Finisher_G1 EX QVA13172 171 ...
Страница 197: ...Inner Finisher G1 EX QVA10470 192 ...