Copier Color | iR-ADV C3330/C3325/C3320 Series |
"Place the originals again." is displayed after starting to copy with
the copy board.
[Symptom]
"Place the originals again." may be displayed repeatedly after putting the original on the copy board to copy without using ADF.
[Cause]
The sensor flag [b] of the Document set sensor moves to the position of sensor ON when ADF is opened vertically.
If the main body is turned ON in a state of opening ADF vertically during returning from sleep (starting up reader/ADF) or in a
state of keeping ADF open vertically, the Document set sensor turned on and it recognizes that an original is in the ADF ("Finishing"
inverts in yellow)[C].
Even the ADF is closed, the control information of booting reader/ADF is still left and the state does not shift to "No original".
Consequently the above mentioned symptom occurs because the device tries to feed the original from the ADF to copy while the
original is placed on the copy board.
The symptom will occur again and again when you try to copy as long as the control information of booting reader/ADF is left.
[Reference] Please open the ADF vertically after displaying [COPY] on the UI. The occurrence of the symptom can be avoided.
[Service work]
Choose the Step A) or B) according to the availability of turning OFF the main power.
A) When the main power cannot be turned OFF, execute the following step.
A-1) Close the ADF and place a paper on the ADF original tray and then take off the paper after the LED (green color) lights [a]
to confirm that the UI screen state changes to "No original" ("Finishing" does not invert in yellow)[b].
[Reference] The copying of the original is possible by moving the original from the copy board to the ADF original tray.
70
Содержание imageRUNNER ADVANCE C3330 Series
Страница 1: ...Trouble Shooting Guide imageRUNNER ADVANCE C3330 Series August 2017 OIP Field Quality Assurance Div ...
Страница 83: ...iR ADV C3325i US 120V QTW07191 78 ...
Страница 85: ...iR ADV C3325i US 120V QTW07191 iR ADV C3330i US 120V G QTX00507 80 ...
Страница 90: ...1 8 Remove 4 screws 1 on the Tray 1 1 9 Remove 5 screws 1 on the undersurface of the Tray 1 85 ...
Страница 97: ...2 12 Remove 5 screws 1 on the undersurface of the Tray 1 2 13 Detach the Tray cover upper 1 92 ...
Страница 105: ...If the symptom does not improve check other causes 100 ...
Страница 124: ...4 Mount the left cover upper and then close the front cover 119 ...
Страница 130: ...7 Make a test copy and check that a jam does not occur If the symptom does not improve check other causes 125 ...
Страница 140: ...3 Remove the inner cover Screw 1 pc Claw 2 pcs 4 Replace the empty sensor lever 1 with the new type Claw 2 pcs 135 ...
Страница 144: ...139 ...
Страница 176: ...Inner Finisher_G1 EX QVA13172 171 ...
Страница 197: ...Inner Finisher G1 EX QVA10470 192 ...