Copier Color | iR-ADV C3330/C3325/C3320 Series |
Method for releasing limited function of "Staple-free Staple" mode
[Symptom]
In case of jam occurrence caused by failure etc. while using "Staple-free Staple" mode, if jam codes shown below occurs two
times in a row, it automatically enters limited function mode. Once it enters limited function mode, "Staple-free Staple" mode can
never be used unless the limited function mode is released. Since the limited function mode cannot be released by the main
power OFF/ON, releasing it in service mode is required.
Jam Code
Sensor Name
1801
Staple-less binding jam (Clinch Motor Drive Sensor error)
1802
Staple-less binding jam (Clinch HP Sensor error)
1803
Staple-less binding jam (Clinch Motor error)
1804
Staple-less binding jam (time-out error of binding operation)
1805
Staple-less binding jam (time-out error of return operation after binding)
[Reference]
- If the same jam code occurs two times in a row, alarm code (61-0002) [a] is reported to the main unit, and it enters the limit
function mode.
- When staple-free staple mode enters limited function mode, message [a] is displayed on LUI.
- In case staple-free staple mode is set while the function is limited, the lamp of the start button changes from [a] to [b], and staple-
free staple printing cannot be executed.
189
Содержание imageRUNNER ADVANCE C3330 Series
Страница 1: ...Trouble Shooting Guide imageRUNNER ADVANCE C3330 Series August 2017 OIP Field Quality Assurance Div ...
Страница 83: ...iR ADV C3325i US 120V QTW07191 78 ...
Страница 85: ...iR ADV C3325i US 120V QTW07191 iR ADV C3330i US 120V G QTX00507 80 ...
Страница 90: ...1 8 Remove 4 screws 1 on the Tray 1 1 9 Remove 5 screws 1 on the undersurface of the Tray 1 85 ...
Страница 97: ...2 12 Remove 5 screws 1 on the undersurface of the Tray 1 2 13 Detach the Tray cover upper 1 92 ...
Страница 105: ...If the symptom does not improve check other causes 100 ...
Страница 124: ...4 Mount the left cover upper and then close the front cover 119 ...
Страница 130: ...7 Make a test copy and check that a jam does not occur If the symptom does not improve check other causes 125 ...
Страница 140: ...3 Remove the inner cover Screw 1 pc Claw 2 pcs 4 Replace the empty sensor lever 1 with the new type Claw 2 pcs 135 ...
Страница 144: ...139 ...
Страница 176: ...Inner Finisher_G1 EX QVA13172 171 ...
Страница 197: ...Inner Finisher G1 EX QVA10470 192 ...