Copier Color | iR-ADV C3330/C3325/C3320 Series |
"Toner cart. may be malfunctioning" message displayed due to a
bottle connector cable failure message displayed due to a bottle
connector cable failure
[Symptom]
" Toner cart. may be malfunctioning " message [A] may appear on the UI of the engine.
[Cause]
When the harness (bottle connector cable) between the DC controller PCB (J135) and the new/old bottle sensor interferes with
the metal sheet [A] of DC controller PCB, no communication can be made with the new/old bottle sensor, resulting in the above
symptom.
[Service work]
1) Remove 2 screws and then remove the cover (Rear upper).
2) Check a condition of the bottle connector cable. If the bottle connector cable interferes with the metal sheet of DC controller
PCB, wrap insulation tape around the bottle connector cable where interfering occurs.
If insulation tape is not available, work on the wiring so that the bottle connector cable does not interfere with the metal sheet of
DC controller PCB.
If the outer cover of the bottle connector cable is damaged, prepare a new bottle connector cable (FM1-D853-000) and replace
the old one.
3) Attach the cover (Rear upper) with the 2 screws.
4) Start the main body and confirm that the symptom does not occur.
If the symptom does not improve, check other causes.
[Service part] FM1-D853 CABLE, BOTTLE CONNECTOR
121
Содержание imageRUNNER ADVANCE C3330 Series
Страница 1: ...Trouble Shooting Guide imageRUNNER ADVANCE C3330 Series August 2017 OIP Field Quality Assurance Div ...
Страница 83: ...iR ADV C3325i US 120V QTW07191 78 ...
Страница 85: ...iR ADV C3325i US 120V QTW07191 iR ADV C3330i US 120V G QTX00507 80 ...
Страница 90: ...1 8 Remove 4 screws 1 on the Tray 1 1 9 Remove 5 screws 1 on the undersurface of the Tray 1 85 ...
Страница 97: ...2 12 Remove 5 screws 1 on the undersurface of the Tray 1 2 13 Detach the Tray cover upper 1 92 ...
Страница 105: ...If the symptom does not improve check other causes 100 ...
Страница 124: ...4 Mount the left cover upper and then close the front cover 119 ...
Страница 130: ...7 Make a test copy and check that a jam does not occur If the symptom does not improve check other causes 125 ...
Страница 140: ...3 Remove the inner cover Screw 1 pc Claw 2 pcs 4 Replace the empty sensor lever 1 with the new type Claw 2 pcs 135 ...
Страница 144: ...139 ...
Страница 176: ...Inner Finisher_G1 EX QVA13172 171 ...
Страница 197: ...Inner Finisher G1 EX QVA10470 192 ...