Copier Color | iR-ADV C3330/C3325/C3320 Series |
Abnormal sound from the registration guide unit during feeding
papers
[Symptom]
In the machines prior to the Countermeasure cut-in serial number in factory described below rubbing sound (squeak) may be
heard from the registration guide unit during pick-up paper operation.
[Cause]
The edge part of sheet metal [1] (whose bent part is raised) for the right front end plate of main body is sharp. Therefore the
rubbing sound may occur in the part which comes into contact with the registration guide unit [2].
[Service work]
When the abovementioned symptom occurs, prepare either of grease Molykote EM-50L (HY9-0007-000) or grease SE1107
(FY9-6036-000) to work following the procedure below.
1) Detach the registration guide unit from the main body referring the Service Manual.
2) Apply grease to the edge part [a] of sheet metal (whose bent part is raised) for the right front end plate of main body.
[Note] Apply grease only to the edge part. Applying amount of grease which covers the edge part and pay attention not to apply
too much. If the grease drops from the edge, it means the amount is too much.
3) Place back the registration guide unit to the main body.
[Service parts]
No.
Part Number
Description
1
Old
HY9-0007-000
Molykote EM-50L
New
2
Old
New
FY9-6036-000
LUBE, SE1107 GREASE
[Countermeasure cut-in serial numbers in factory]
Model
Serial number
iR-ADV C3330 230V
QTZ04315
iR-ADV C3325 230V
QUB02081
iR-ADV C3320 230V
QUC05164
iR-ADV C3330 CN 220V
QUE01143
iR-ADV C3325 CN 220V
QUF01378
113
Содержание imageRUNNER ADVANCE C3330 Series
Страница 1: ...Trouble Shooting Guide imageRUNNER ADVANCE C3330 Series August 2017 OIP Field Quality Assurance Div ...
Страница 83: ...iR ADV C3325i US 120V QTW07191 78 ...
Страница 85: ...iR ADV C3325i US 120V QTW07191 iR ADV C3330i US 120V G QTX00507 80 ...
Страница 90: ...1 8 Remove 4 screws 1 on the Tray 1 1 9 Remove 5 screws 1 on the undersurface of the Tray 1 85 ...
Страница 97: ...2 12 Remove 5 screws 1 on the undersurface of the Tray 1 2 13 Detach the Tray cover upper 1 92 ...
Страница 105: ...If the symptom does not improve check other causes 100 ...
Страница 124: ...4 Mount the left cover upper and then close the front cover 119 ...
Страница 130: ...7 Make a test copy and check that a jam does not occur If the symptom does not improve check other causes 125 ...
Страница 140: ...3 Remove the inner cover Screw 1 pc Claw 2 pcs 4 Replace the empty sensor lever 1 with the new type Claw 2 pcs 135 ...
Страница 144: ...139 ...
Страница 176: ...Inner Finisher_G1 EX QVA13172 171 ...
Страница 197: ...Inner Finisher G1 EX QVA10470 192 ...