Copier Color | iR-ADV C3330/C3325/C3320 Series |
After turning ON the main switch, Abnormal noise/the display of
the message "Close the upper right cover of the drawer. " may
occur due to the disconnection of the connector.
[Symptom]
After turning on the main switch, the Abnormal noise (flicking noise) from the right side of the main body [A] and the display of
the message "Close the upper right cover of the drawer." on UI screen may occur.
[Cause]
J124[1] for DC controller PCB [A] and J602[2] for Deck driver PCB [B] communicate the detection of Paper Surface Sensor and
the upper right cover switch of cassette paper Pickup Assembly. The symptom occurs when a connector which is one of the two
above is disconnected.
-Paper Surface Sensor of the cassette paper Pickup Assembly is unable to detect the existence of media, so cassette 2 lift does
not stop and keeps on moving up and then the Abnormal noise occurs.
-The upper right cover switch is unable to detect the state of the cover closed, so the message "Close the upper right cover of
the drawer." is showed and the Abnormal noise is stopped.
[Refer] J124 is the connector for the DC controller PCB which is connected to J602 for the Deck driver PCB.
[Service work]
1) Check if J124 connector of DC controller PCB and J602 connector of Deck driver PCB are not disconnected.
If no connector is disconnected, check other factors (disconnection of cable and unit etc.)
2) Start the main body and, please confirm that a phenomenon does not occur.
3) If the symptom does not improve, then check other factors.
103
Содержание imageRUNNER ADVANCE C3330 Series
Страница 1: ...Trouble Shooting Guide imageRUNNER ADVANCE C3330 Series August 2017 OIP Field Quality Assurance Div ...
Страница 83: ...iR ADV C3325i US 120V QTW07191 78 ...
Страница 85: ...iR ADV C3325i US 120V QTW07191 iR ADV C3330i US 120V G QTX00507 80 ...
Страница 90: ...1 8 Remove 4 screws 1 on the Tray 1 1 9 Remove 5 screws 1 on the undersurface of the Tray 1 85 ...
Страница 97: ...2 12 Remove 5 screws 1 on the undersurface of the Tray 1 2 13 Detach the Tray cover upper 1 92 ...
Страница 105: ...If the symptom does not improve check other causes 100 ...
Страница 124: ...4 Mount the left cover upper and then close the front cover 119 ...
Страница 130: ...7 Make a test copy and check that a jam does not occur If the symptom does not improve check other causes 125 ...
Страница 140: ...3 Remove the inner cover Screw 1 pc Claw 2 pcs 4 Replace the empty sensor lever 1 with the new type Claw 2 pcs 135 ...
Страница 144: ...139 ...
Страница 176: ...Inner Finisher_G1 EX QVA13172 171 ...
Страница 197: ...Inner Finisher G1 EX QVA10470 192 ...