pg. 55
1. Open the feeder cover.
2. Remove 2 hooks [2] of the separation pad unit holder to remove the separation pad unit holder.
3. Attach the separation pad unit holder (FL3-5538-000). Due the measure, the color of the separation pad
unit holder has been changed from black to white.
FL3-5538 HOLDER, SEPARATION PAD UNIT
<E020>
Title
E020-0x60/E020-1x60 /340001/340002/340006 Alarm Code due to the tension spring coming off
Symptom
E020-0x60/E020-1x60 or Alarm Code (340001/340002/340006) may occur.
- E020-0x60: ATR patch not formed correctly, or patch sensor error
- E020-1x60: Abnormal patch reading value detected (x=0: Y, 1: M, 2: C, 3: Bk)
- 340001/340002 Alarm code: Auto registration adjustment alarm (a soil or scar on the belt is erroneously
detected as a pattern, and accordingly deviation occurs in read-in data.)