NOTE:
• A value between 0 and 99999 can be set, but make sure to set the value instructed by the Support Dept. of your sales company.
Operations are not guaranteed when value other than the above is set.
• The displayed setting is not changed simply by changing the setting or pressing [DEFAULT].
It is necessary to exit the DBG-LOG screen once by pressing the [Reset] key, etc. and then display it again, after performing
these operations.
Executing Auto Saving (Reference Example)
An example of executing auto saving using LOG-TRIG is shown below so that you can experience the log collection work.
It is an example of log collection in the event of jam in the Delivery Assembly during copy operation.
1. Connect a USB device to the machine while the machine is ready for operation.
2. Set "301" in the following service mode (Lv.2).
• COPIER > Function > DBG-LOG > LOG-TRIG
3. Make a copy. Open the Delivery Feed Assembly before paper is delivered from the Delivery Assembly to generate a jam.
4. When a jam occurs, confirm "Storing System Information..." is displayed at the bottom of the Control Panel.
● Initial setting of the network packet log collection function
When collecting the network packet logs, configure the initial settings as needed.
Setting the overwrite function
1. To enable this function, set "1" in the following service mode (Lv.2).
Service mode > COPIER > TEST > NET-CAP > OVERWRIT
NOTE:
When this setting is enabled, old logs will be overwritten. If the symptom cannot be reproduced, disable this setting (setting value:
0) and secure logs (save them using SST or USB).
After securing the logs, enable the setting (setting value: 1) again.
Behavior when HDD reaches the limit
When this setting is enabled (setting value: 1), the following behaviors will occur when the HDD reaches the limit.
• When overwrite setting is ON
• The oldest packet file is deleted. This "oldest file" is judged not by the date and time allocated to the file but
by the last update time of the file.
• If the HDD reaches the maximum size while retrieving packets, the oldest file will be deleted, and CAPSTATE
of the capture, which continues the retrieval process for the file which is being saved, remains "RUNNING".
• When overwrite setting is OFF
• The capture is stopped.
• The CAPSTATE of the capture will be "HDDFULL". However, STT-STP will remain as Start (1) status. By
changing STT-STP (0) to STTSTP (1), the capture resumes.
• When the capture resumes, the capture starts if HDDFULL has been solved.
• The CAPSTATE of the capture will be "RUNNING".
• If HDDFULL has not been solved, an error is generated as the result of resuming the capture.
• The CAPSTATE of the capture remains "HDDFULL".
• If the capture is stopped while the CAPSTATE is "HDDFULL", the CAPSTATE of the capture remains "STOP".
Setting the encryption function
1. To enable this function, set "2" in the following service mode (Lv.2).
COPIER > TEST > NET-CAP > ENCDATA
• 0: Encrypted when data is extracted (factory default setting).
• 1: Not encrypted when data is extracted.
• 2: When data is extracted, a ciphertext file and a plaintext file are extracted.
The extension of extracted packet data will be "XXX.can" when encryption settings are enabled.
The extension of extracted packet data will be "XXX.cap" when encryption settings are disabled.
This setting only applies when extracting data by the USB flash drive.
NOTE:
When SST is used to collect data, both plaintext data and ciphertext data are extracted, and this setting is ignored.
6. Troubleshooting
256
Содержание imageRUNNER ADVANCE 525 I
Страница 1: ...Revision 1 0 iR ADV 715 615 525 Series Service Manual ...
Страница 15: ...Product Overview 1 Product Lineup 6 Specifications 9 Parts Name 14 ...
Страница 75: ... Paper Path Model with Built in Finisher Paper Path Model with Built in Finisher 2 Technology 65 ...
Страница 95: ...Periodical Service 3 Periodically Replaced Parts 86 Consumable Parts List 87 ...
Страница 120: ... Procedure 1 3x Removing the Front Cover Procedure 1 2x 2 4 Parts Replacement and Cleaning 110 ...
Страница 122: ...2 1x 3x 3 4 Parts Replacement and Cleaning 112 ...
Страница 124: ...1 2 3 4 Parts Replacement and Cleaning 114 ...
Страница 125: ...4 Removing the Control Panel Procedure 1 2 4 Parts Replacement and Cleaning 115 ...
Страница 126: ...3 2x 4 3x 2x 4 Parts Replacement and Cleaning 116 ...
Страница 127: ...5 6 CAUTION Do not drop the Control Panel while turning over it 4 Parts Replacement and Cleaning 117 ...
Страница 128: ...7 1x 1x 8 2x 4 Parts Replacement and Cleaning 118 ...
Страница 130: ...1 2 3 2x 4 Parts Replacement and Cleaning 120 ...
Страница 136: ... Procedure 1 2 1x NOTE Check the position of the claw in the figure 4 Parts Replacement and Cleaning 126 ...
Страница 169: ...23 Press the A part and remove the Feed Frame Unit A 4 Parts Replacement and Cleaning 159 ...
Страница 180: ...22 Press the A part and remove the Feed Frame Unit A 4 Parts Replacement and Cleaning 170 ...
Страница 190: ...21 Press the A part and remove the Feed Frame Unit A 4 Parts Replacement and Cleaning 180 ...
Страница 196: ...3 4 Parts Replacement and Cleaning 186 ...
Страница 204: ...2 4x 16x 3 4 Parts Replacement and Cleaning 194 ...
Страница 210: ... Procedure 1 2x 1x 4 Parts Replacement and Cleaning 200 ...
Страница 211: ...2 2x 3x 1x 4 Parts Replacement and Cleaning 201 ...
Страница 212: ...3 CAUTION Do not touch the speaker part A of the Fax unit A 2x 1x 4 Parts Replacement and Cleaning 202 ...
Страница 215: ...Image Formation System Removing the Transfer Unit Procedure 1 2 3 1x 4 Parts Replacement and Cleaning 205 ...
Страница 217: ...2 1x 4 Parts Replacement and Cleaning 207 ...
Страница 221: ...5 Removing the Low Voltage Power Supply PCB on page 195 Procedure 1 4x 1x 4 Parts Replacement and Cleaning 211 ...
Страница 223: ...2 1x 3 4 1x 4 Parts Replacement and Cleaning 213 ...
Страница 226: ... Procedure 1 2 3 1x 4 Parts Replacement and Cleaning 216 ...
Страница 227: ...4 11x 5 1x 6 1x 4 Parts Replacement and Cleaning 217 ...
Страница 228: ...7 6x 1x 8 4 Parts Replacement and Cleaning 218 ...
Страница 238: ... Procedure 1 2x 2x 2 4 Parts Replacement and Cleaning 228 ...
Страница 240: ... Procedure 1 2 3 1x 4 Parts Replacement and Cleaning 230 ...
Страница 241: ...4 5 3x 1x 2x 4 Parts Replacement and Cleaning 231 ...
Страница 242: ...Adjustment 5 Pickup Feed System 233 Actions at Parts Replacement 235 ...
Страница 251: ...Troubleshooting 6 Initial Check 242 Test Print 243 Debug Log 248 ...
Страница 277: ...Error Jam Alarm 7 Overview 268 Error Code 271 Error Code FAX 324 Alarm Code 327 Jam Code 336 ...
Страница 598: ...6 7 8 1x 9 NOTE Use the screw removed in steps 3 1x 9 Installation 588 ...
Страница 602: ...2 3 2x 4 3x 2x 9 Installation 592 ...
Страница 603: ...5 6 7 1x 1x 8 2x 9 Installation 593 ...
Страница 604: ...9 6x 10 2x Installing the NFC Kit 1 1x 9 Installation 594 ...
Страница 605: ...2 1x 3 TP M3x4 1x 4 1x 9 Installation 595 ...
Страница 606: ... Installing the Control Panel 1 2x 2 6x 9 Installation 596 ...
Страница 607: ...3 2x 4 1x 1x 5 6 9 Installation 597 ...
Страница 619: ...21 22 Without the Finisher With the Finisher 9 Installation 609 ...
Страница 638: ...APPENDICES Service Tools 629 General Circuit Diagram 630 Soft counter specifications 635 Removal 639 ...
Страница 639: ...Service Tools Special Tools None Solvents and Oils None Service Tools 629 ...