Chapter 2
2-10
F-2-32
2) Slide the right deck and Cassett3/4 halfway out, and open the lower right
cover. Then, remove the pickup roller pressure release spacers [1].
F-2-33
3) After removing all spacers, slide the deck/cassette in and close the lower
right cover.
4) Attach the door tape of the upper right cover with the screw, and close the
upper right cover.
2.2.8 Attaching Deck Pressure Plate
0015-4663
iR5065 / iR 5055 / iR5075 / / /
1) Press the release button of the left deck and slide the left deck out.
2) Attach the deck pressure plate [1] with the screw (RS tightening; M4X8)
[2].
F-2-34
3) Close the left deck.
2.2.9 Setting Toner Container
0015-4664
iR5065 / iR 5055 / iR5075 / / /
1) Take out the toner container from the packing box.
2) After opening the toner replacement cover [1], pull down the lock lever
[2] in the direction of the arrow.
F-2-35
3) Hold the toner container [1] as shown in the figure below, and remove the
cap [2] from the container by rotating the cap in the direction of the arrow.
F-2-36
4) Hold the toner container with its mouth [1] at the right side, and set it into
the supply case [2] of the host machine horizontally.
F-2-37
5) Slide the lock lever [1] upward to lock the toner container [2] in place.
F-2-38
6) Close the toner replacement cover.
2.2.10 Connecting the Cable
0015-4665
iR5065 / iR 5055 / iR5075 / / /
1) Attach the wire saddle [1] onto the upper rear cover.
MEMO;
The spacers are being pressured while the deck/cassette is set; thus, it is
hard to remove them.
Therefore, release the pressure by sliding the deck/cassette halfway out.
Do not shake the toner container.
If setting the toner container that has been shaken to the host machine, the
toner overflow within the machine may occur.
By shaking the container, the toner fluidity increases. As a result, toner is
supplied swiftly to the machine with the toner supply operation, causing the
foregoing symptoms.
[1]
[1]
[1]
[2]
When turning on the main power switch without setting toner container, the
toner level meter on the control panel shows 25 % or less. Make sure that the
toner container is set in the host machine before turning on the main power
switch.
[1]
[2]
[1]
[2]
[1]
[2]
[2]
[1]
Содержание imageRUNNER 5065 series
Страница 1: ...Feb 26 2007 Service Manual iR5075 5065 5055 Series ...
Страница 2: ......
Страница 6: ......
Страница 27: ...Chapter 1 Introduction ...
Страница 28: ......
Страница 30: ......
Страница 52: ......
Страница 53: ...Chapter 2 Installation ...
Страница 54: ......
Страница 98: ...Chapter 2 2 42 ...
Страница 99: ...Chapter 3 Basic Operation ...
Страница 100: ......
Страница 102: ......
Страница 108: ......
Страница 109: ...Chapter 4 Main Controller ...
Страница 110: ......
Страница 112: ......
Страница 129: ...Chapter 5 Original Exposure System ...
Страница 130: ......
Страница 162: ......
Страница 163: ...Chapter 6 Laser Exposure ...
Страница 164: ......
Страница 166: ......
Страница 172: ......
Страница 173: ...Chapter 7 Image Formation ...
Страница 174: ......
Страница 178: ......
Страница 210: ......
Страница 211: ...Chapter 8 Pickup Feeding System ...
Страница 212: ......
Страница 263: ...Chapter 9 Fixing System ...
Страница 264: ......
Страница 268: ......
Страница 307: ...Chapter 10 External and Controls ...
Страница 308: ......
Страница 312: ......
Страница 321: ...Chapter 10 10 9 F 10 8 ...
Страница 345: ...Chapter 11 MEAP ...
Страница 346: ......
Страница 348: ......
Страница 389: ...Chapter 12 RDS ...
Страница 390: ......
Страница 392: ......
Страница 399: ...Chapter 13 Maintenance and Inspection ...
Страница 400: ......
Страница 402: ......
Страница 411: ...Chapter 14 Standards and Adjustments ...
Страница 412: ......
Страница 440: ......
Страница 441: ...Chapter 15 Correcting Faulty Images ...
Страница 442: ......
Страница 444: ......
Страница 470: ......
Страница 471: ...Chapter 16 Self Diagnosis ...
Страница 472: ......
Страница 474: ......
Страница 493: ...Chapter 17 Service Mode ...
Страница 494: ......
Страница 496: ......
Страница 552: ......
Страница 553: ...Chapter 18 Upgrading ...
Страница 554: ......
Страница 556: ......
Страница 572: ...Chapter 18 18 16 F 18 29 2 Click Start F 18 30 3 When the session has ended click OK ...
Страница 587: ...Chapter 18 18 31 F 18 59 2 Select the data to download F 18 60 3 Click Start ...
Страница 589: ...Chapter 19 Service Tools ...
Страница 590: ......
Страница 591: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 List of Special Tools 19 1 19 1 2 List of Solvents Oils 19 1 ...
Страница 592: ......
Страница 595: ...Feb 26 2007 ...
Страница 596: ......